Structural Performance Of Closed Cooling Tower Equipment
- Efficient heat exchanges:
The oval aluminum alloy tube is used, and all tubes are welded into coils after being passed away. To ensure that it is not leaked, each set of pipes do 1.6MPa's air pressure test in the water. The use of oval tubes can increase the surface area and water -receiving area of the heat exchanges, the pipeline is interrupted, and the reasonable pipeline spacing design and spray water form a uniform water film on each tube wall Essence The air and cooling water outside the closed cooling tower pipe use reverse flow. The tube layout of the ellipse and the cross -arrangement of the cross -arranged pipes make the plate have excellent heat exchange effect and lower air resistance.
- Efficient spray water circulation system:
The latest development and development of ABS special spraying, with the advantages of large spray water volume, uniform water distribution, and not blocking. A reasonable cloth spraying height and nozzle laying can form a uniform water film on the outer wall of the coil. Avoid wall flow.
The spray water circulation system is specially equipped with a special stains to slow down the corrosion and increase the heat exchange effect.
Outdoor circulating water pumps are used to reduce energy consumption and reduce maintenance.
- Reasonable water and gas ratio: According to the research results of the cooling tower for many years of cooling tower experts from Shanghai Jiaotong University, the spray circulating water volume and cooling air volume of the tower are the best choice.
- Efficient water collection device, water -saving effect is good:
The three -dimensional water collection device made from the latest FRP material has small air resistance and high water collection efficiency. It is more than 99.99 % of the circulating water volume. In order to facilitate the inside of the cooling tower, the water collection device is designed to be demolished. The overall water consumption of the closed cooling tower can be controlled between 0.5-1%and is one-fifth of the water consumption of the closed cooling tower.
- Efficient and low noise fan:
The wide leaves, long string long, and spatial distorted aluminum alloy cooling tower are used to win the national invention award. The fan and motor adopt a direct connection type, without deceleration and convenient maintenance. The motor uses outdoor output high -temperature closed motors.
6, solid anticorrosive tower body: In order to keep the closed cooling tower running normally in the worst environment, the structure of the tower body and the water collection chassis are all made of stainless steel plate. The cylinder uses a corrosive glass fiber reinforcement component, and all connectors in the closed cooling tower are made of stainless steel. The model -closed cooling tower series adopts modular design, which is conducive to layout.