Closed circuit Cooling Tower also named Evaporative cooler. It is the type of cooling tower placed the heat exchange tube inner the tower to ensure the cooling effect by circulation of air, spray water and circulating water.
Einführung
Closed circuit Cooling Tower also named Evaporative cooler. It is the type of cooling tower placed the heat exchange tube inner the tower to ensure the cooling effect by circulation of air, spray water and circulating water.

| Hauptkomponenten | |
| Spule | Hergestellt aus hochwertigen nahtlosen Stahlrohren. Die Spuleneinheit wird aus SS-304/316L Edelstahl hergestellt. Der maximale Druck unserer Spulen kann bis zu 32Mpa erreichen. |
| Sprühpumpe | Abgedichtet durch eine hochwertige, rotierende, nicht begrenzte Maschinendichtung, keine Leckage, lange Lebensdauer, kleine Leistung, großes Durchflussvolumen, geringer Lärm und hohe Leistung. |
| Fan | Axialer Typ; Propeller aus Aluminiumlegierung |
| Gehäuse | SS-304/316L oder importiertes Blech aus Aluminium-Zink-Legierung, Mg-Al-Zink-Blech |
| Elektrisches Wasseraufbereitungsgerät | Reinigen Sie den Wasserkreislauf, um die Bildung von Kesselstein auf der Oberfläche von Spulen und PVC-Füllungen zu vermeiden. |
| Abnehmbarer Drift-Eliminator | PVC-Material; Stellen Sie sicher, dass der Wasserverlust weniger als 0,002% beträgt. |
| Kühlturm-Füllkörper | 100% Original Material PVC Infill, spezielles Design mit großem Kühleffekt |
Closed Water Cooling Tower Advantage
1. Combination Closer approach to wet bulb temperature and reduce fouling improve process efficiency
2. Lower process temperatures ,less required space ,and lower energy consumption.
3. Through Systems Reduces environmental impact ,saving up to 95% of the cooling water .
4. Reduced installed Cost And Space Requirements Effectively combines the function of a cooling tower and heat exchanger into one piece of equipment ,reduce required piping and system complexity.
VS open cooling tower
Closed circuit cooling tower
1. The whole pipeline system is closed circulation, and the circulating water is distilled water, which can make the vacuum furnace heat exchanger and small pipelines not scale, pollute, or corrode, and almost make the vacuum furnace Double the life.
2. There is almost no water consumption in circulating water. The same type of equipment saves about 7,000 tons of water per year.
3. Low operating costs and low maintenance
Open cooling towers
1. It is necessary to excavate 1-2 20 cubic meters of groundwater pool. Due to the water drop and open head loss
2.the power consumption is more than that of closed towers. Two sets of pumps are needed, which consumes a lot of electricity.
Facilities and equipment

Hot Tags: closed circuit cooling towers, suppliers, manufacturers, customized, price, Cross Flow Cooling Tower manufacturers, Hybrid Closed Circuit Cooling Tower, Cooling Tower Systems factory, Closed Circuit Cooling Towers, Anti noise Square Cooling Tower, flow tech cooling tower