{"id":2175,"date":"2023-12-14T13:53:53","date_gmt":"2023-12-14T05:53:53","guid":{"rendered":"http:\/\/192.168.1.196:292\/?p=2175"},"modified":"2024-08-05T16:17:12","modified_gmt":"2024-08-05T08:17:12","slug":"closed-circuit-industrial-cooling-tower","status":"publish","type":"post","link":"https:\/\/gewabintech.com\/de\/products\/closed-circuit-cooling-tower\/counter-flow-cooling-tower\/closed-circuit-industrial-cooling-tower\/","title":{"rendered":"Industrieller K\u00fchlturm mit geschlossenem Kreislauf"},"content":{"rendered":"<p><strong>Aufbau und Funktionsweise<\/strong><\/p>\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" width=\"541\" height=\"389\" src=\"\/wp-content\/uploads\/2023\/12\/4ca1c48265401af2bc9e.jpg\"  class=\"wp-image-3138\" title=\"Illustration eines industriellen K\u00fchlturms mit geschlossenem Kreislauf\" alt=\"Closed Circuit Industrial Cooling Tower\u63d2\u56fe\" \/><\/figure>\n<p>Im Betrieb wird das K\u00fchlmedium von einer Hauptumw\u00e4lzpumpe umgew\u00e4lzt, die den Durchfluss zwischen dem W\u00e4rmetauscher und der Anlage sicherstellt. Das Wasser wird auf den W\u00e4rmetauscher gespr\u00fcht, um einen gleichm\u00e4\u00dfigen Wasserfilm auf der W\u00e4rme\u00fcbertragungsfl\u00e4che zu bilden. Kalte Luft str\u00f6mt durch den darunter liegenden Lufteinlass \u00fcber die Oberfl\u00e4che des W\u00e4rmetauschers in den Turm ein. Bei diesem Vorgang finden zwei Arten des W\u00e4rmeaustauschs statt. Zum einen die W\u00e4rme\u00fcbertragung zwischen der kalten Luft und dem K\u00fchlmedium sowie der W\u00e4rmeaustausch mit dem Dampf und die W\u00e4rmeaufnahme durch den Wasserspr\u00fchnebel. Hei\u00dfe Luft wird aus dem Turm in die Atmosph\u00e4re abgeleitet. Ein weiterer Teil des Wassers flie\u00dft in das Sammelbecken unterhalb des Turms und wird anschlie\u00dfend in das Spr\u00fchsystem gepumpt. Das K\u00fchlmedium im Wechselwirkungsw\u00e4rmetauscher wird dabei gek\u00fchlt.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Vorteile<\/strong><\/p>\n<p>1. Es wird das Inverter-Argon-Lichtbogenschwei\u00dfverfahren angewendet, und das Produkt wird mehrfach einer Druckpr\u00fcfung von 2,75 MPa unterzogen, um die Schwei\u00dfqualit\u00e4t und die allgemeine Druckfestigkeit sicherzustellen.<\/p>\n<p>2. Das aus legiertem verzinktem Stahlblech gefertigte Geh\u00e4use zeichnet sich durch eine gute Feuchtigkeitsbest\u00e4ndigkeit, Oxidationsbest\u00e4ndigkeit und Korrosionsbest\u00e4ndigkeit aus.<\/p>\n<p>3. Es kommen ein spezieller K\u00fchlturmmotor, ein Ventilator sowie eine einzigartige Befeuchtungs- und Abscheidetechnologie zum Einsatz.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Gebrauchsanweisung<\/strong><\/p>\n<p>1. Bevor Sie sich f\u00fcr ein Produkt entscheiden, k\u00f6nnen Sie uns die Wassereintrittstemperatur, die Wasseraustrittstemperatur und die Luft-Feuchtkugeltemperatur mitteilen.<\/p>\n<p>2. Unsere Produkte sind f\u00fcr den Betrieb bei -50 \u00b0C ausgelegt; liegt die k\u00e4lteste Durchschnittstemperatur unter -10 \u00b0C, sollten Sie uns dies bei der Bestellung mitteilen, damit wir Ma\u00dfnahmen zum Frostschutz ergreifen k\u00f6nnen.<\/p>\n<p>3. Die Tr\u00fcbung des Umw\u00e4lzwassers betr\u00e4gt weniger als 50 mg\/l; es ist frei von \u00d6l und Verunreinigungen.<\/p>\n<p>4. Die Wassereintrittstemperatur liegt unter 60 \u00b0C.<\/p>\n<p>5. Die Zu- und Ablaufrohre lassen sich um 90\u00b0, 180\u00b0 und 270\u00b0 drehen.<\/p>\n<p>6. Der Winkel der L\u00fcfterfl\u00fcgel ist einstellbar, um einen einheitlichen Winkel zu gew\u00e4hrleisten.<\/p>\n<p>7. Der Nennstrom des Motors darf nicht \u00fcberschritten werden.<\/p>\n<p>8. Achten Sie auf Hitze und Druck.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Unsere Dienstleistungen<\/strong><\/p>\n<p>Dienstleistungen vor dem Verkauf:&nbsp; &nbsp;<\/p>\n<p>(1) Den Kunden erkl\u00e4ren, wie sie unsere Produkte verwenden k\u00f6nnen<\/p>\n<p>(2) Kunden bei der Auswahl des besten und wirtschaftlichsten Produkts beraten, damit sich die Investition in kurzer Zeit amortisiert.  Kundendienst:&nbsp;&nbsp;<\/p>\n<p>Die Qualit\u00e4tskontrolle muss streng \u00fcberwacht werden. &nbsp;<\/p>\n<p>Kundendienst:&nbsp; &nbsp;<\/p>\n<p>In der Regel betr\u00e4gt unsere Produktgarantie 18 Monate ab Verlassen des Werks oder 12 Monate ab Installation. Innerhalb dieser Frist \u00fcbernimmt unser Werk die Verantwortung f\u00fcr alle defekten Teile.<\/p>\n<p>(3) Regelm\u00e4\u00dfiger Kontakt zu den Kunden. Anpassung unserer Produkte auf Grundlage des Kundenfeedbacks.<\/p>\n<p>&nbsp;<\/p>\n<p>Beliebte Suchbegriffe: Industriek\u00fchlturm mit geschlossenem Kreislauf, Lieferanten, Hersteller, ma\u00dfgeschneiderte L\u00f6sungen, Preis, Hersteller von HLK-K\u00fchlt\u00fcrmen, Hersteller von K\u00fchlt\u00fcrmen und adiabatischen Fl\u00fcssigkeitsk\u00fchlern, Industriek\u00fchlturm mit geschlossenem Kreislauf, Werk f\u00fcr K\u00fchlt\u00fcrme und adiabatische Fl\u00fcssigkeitsk\u00fchler, Preis f\u00fcr Wasserk\u00fchlturm, adiabatische Fl\u00fcssigkeitsk\u00fchler<\/p>","protected":false},"excerpt":{"rendered":"<p>Structure and working principle During operation, the cooling medium is driven by a main circulating pump circulating flow between the heat exchanger and the equipment. The water is sprayed on the heat exchanger to uniformly form a water film on the heat exchange surface. Cold air enters the tower from the underlying air inlet through the surface of the heat exchanger surface. There are two methods of heat exchange in this process. Heat transfer between the cold air and the cooling medium, as well as the heat exchange of the steam and the heat absorption of the water spray. Hot air is vented from the air to the atmosphere. Other water flows into the sink below the tower. Then pump them into the sprinkler system. The cooling medium in the reciprocating heat exchanger is cooled. &nbsp; Advantages 1. Adopt the inverter argon arc welding process and pass the 2.75mpa pressure test for many times to ensure the welding quality and overall pressure resistance. 2. The alloy galvanized steel sheet of the shell has good moisture resistance, oxidation resistance and corrosion resistance. 3. Cooling tower special motor, fan and unique drenching and elimination technology are adopted &nbsp; Using instruction 1. Before you choose the product, you can provide us with the inlet water temperature, the outlet water temperature, and the air wet bulb temperature. 2. Our products can run at -50 \u00b0 C, the coldest average temperature is below -10 \u00b0 C, you should tell us when ordering, we will take anti-ice measures. 3. Circulating water turbidity is less than 50 mg \/ L, free of oil and impurities. 4. The inlet water temperature is below 60 \u00b0C. 5. The inlet and outlet pipes can be rotated by 90\u00b0, 180\u00b0 and 270\u00b0. 6. The fan blade angle is adjustable to ensure the same angle. 7. Do not exceed the rated current of the motor. 8. Pay attention to fire and pressure. &nbsp; Our Services Before-sale services:&nbsp; &nbsp; (1) Tell customers how to use our products (2) Guide customers to choose the best and economic product, recover the investment within short time.&nbsp; In-Sale services:&nbsp;&nbsp; Quality control must be inspected strictly. &nbsp; After-sale services:&nbsp; &nbsp; Usually, our product warranty is 18 months after leaving factory or 12 months after installation. within this months, all parts broken will be responsible for our factory. (3) Regular contact with customers. Update our products based on the feedback of customers. &nbsp; Hot Tags: closed circuit industrial cooling tower, suppliers, manufacturers, customized, price, HVAC Cooling Tower manufacturers, Cooling Towers And Adiabatic Fluid Coolers manufacturers, Closed circuit industrial cooling tower, Cooling Towers And Adiabatic Fluid Coolers factory, Water Cooling Tower pric, Adiabatic Fluid Coolers<\/p>","protected":false},"author":1,"featured_media":2148,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[46],"tags":[],"acf":[],"_links":{"self":[{"href":"https:\/\/gewabintech.com\/de\/wp-json\/wp\/v2\/posts\/2175"}],"collection":[{"href":"https:\/\/gewabintech.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/gewabintech.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/de\/wp-json\/wp\/v2\/comments?post=2175"}],"version-history":[{"count":5,"href":"https:\/\/gewabintech.com\/de\/wp-json\/wp\/v2\/posts\/2175\/revisions"}],"predecessor-version":[{"id":3893,"href":"https:\/\/gewabintech.com\/de\/wp-json\/wp\/v2\/posts\/2175\/revisions\/3893"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/de\/wp-json\/wp\/v2\/media\/2148"}],"wp:attachment":[{"href":"https:\/\/gewabintech.com\/de\/wp-json\/wp\/v2\/media?parent=2175"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/gewabintech.com\/de\/wp-json\/wp\/v2\/categories?post=2175"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/gewabintech.com\/de\/wp-json\/wp\/v2\/tags?post=2175"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}