{"id":2283,"date":"2023-12-18T09:19:27","date_gmt":"2023-12-18T01:19:27","guid":{"rendered":"http:\/\/gewabin.wangluocloud.com\/?p=2283"},"modified":"2024-08-06T10:29:51","modified_gmt":"2024-08-06T02:29:51","slug":"closed-circuit-cooling-towers","status":"publish","type":"post","link":"https:\/\/gewabintech.com\/de\/products\/closed-circuit-cooling-tower\/cross-flow-cooling-tower\/closed-circuit-cooling-towers\/","title":{"rendered":"K\u00fchlt\u00fcrme mit geschlossenem Kreislauf"},"content":{"rendered":"<p><strong>Einf\u00fchrung<\/strong><\/p>\n<p>Closed circuit&nbsp;Cooling Tower also named Evaporative cooler. It is the type of cooling tower placed the heat exchange tube inner the tower to ensure the cooling effect by circulation of air, spray water and circulating water.<\/p>\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" width=\"554\" height=\"554\" src=\"\/wp-content\/uploads\/2023\/12\/cbcad3dddc2ccdffd39f.jpg\"  class=\"wp-image-3428\" srcset=\"https:\/\/gewabintech.com\/wp-content\/uploads\/2023\/12\/cbcad3dddc2ccdffd39f.jpg 554w, https:\/\/gewabintech.com\/wp-content\/uploads\/2023\/12\/cbcad3dddc2ccdffd39f-150x150.jpg 150w\" sizes=\"(max-width: 554px) 100vw, 554px\" title=\"Closed Circuit Cooling Towers\u63d2\u56fe\" alt=\"Closed Circuit Cooling Towers\u63d2\u56fe\" \/><\/figure>\n<\/div>\n<p>&nbsp;<\/p>\n<table class=\"table\" border=\"1\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"2\" rowspan=\"1\" height=\"35\"><strong>Hauptkomponenten<\/strong><\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Spule<\/td>\n<td height=\"35\">Hergestellt aus hochwertigen nahtlosen Stahlrohren. Die Spuleneinheit wird aus SS-304\/316L Edelstahl hergestellt. Der maximale Druck unserer Spulen kann bis zu 32Mpa erreichen.<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Spr\u00fchpumpe<\/td>\n<td height=\"35\">Abgedichtet durch eine hochwertige, rotierende, nicht begrenzte Maschinendichtung, keine Leckage, lange Lebensdauer, kleine Leistung, gro\u00dfes Durchflussvolumen, geringer L\u00e4rm und hohe Leistung.<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Fan<\/td>\n<td height=\"35\">Axialer Typ; Propeller aus Aluminiumlegierung<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Geh\u00e4use<\/td>\n<td height=\"35\">SS-304\/316L oder importiertes Blech aus Aluminium-Zink-Legierung, Mg-Al-Zink-Blech<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Elektrisches Wasseraufbereitungsger\u00e4t<\/td>\n<td height=\"35\">Reinigen Sie den Wasserkreislauf, um die Bildung von Kesselstein auf der Oberfl\u00e4che von Spulen und PVC-F\u00fcllungen zu vermeiden.<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Abnehmbarer Drift-Eliminator<\/td>\n<td height=\"35\">PVC-Material; Stellen Sie sicher, dass der Wasserverlust weniger als 0,002% betr\u00e4gt.<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">K\u00fchlturm-F\u00fcllk\u00f6rper<\/td>\n<td style=\"word-break: break-all;\" height=\"35\">100% Original Material PVC Infill, spezielles Design mit gro\u00dfem K\u00fchleffekt<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><strong>Closed Water Cooling Tower&nbsp;Advantage<\/strong><\/p>\n<p>1. Combination Closer approach to wet bulb temperature and reduce fouling improve process efficiency<\/p>\n<p>2. Lower process temperatures ,less required space ,and lower energy consumption.<\/p>\n<p>3. Through Systems Reduces environmental impact ,saving up to 95% of the cooling water .<\/p>\n<p>4. Reduced installed Cost And Space Requirements Effectively combines the function of a cooling tower and heat exchanger into one piece of equipment ,reduce required piping and system complexity.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>VS open cooling tower<\/strong><\/p>\n<p><strong>Closed circuit cooling tower<\/strong><\/p>\n<p>1. The whole pipeline system is closed circulation, and the circulating water is distilled water, which can make the vacuum furnace heat exchanger and small pipelines not scale, pollute, or corrode, and almost make the vacuum furnace Double the life.<\/p>\n<p>2. There is almost no water consumption in circulating water. The same type of equipment saves about 7,000 tons of water per year.<\/p>\n<p>3.&nbsp;Low operating costs and low maintenance<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Open cooling towers<\/strong><\/p>\n<p>1. It is necessary to excavate 1-2 20 cubic meters of groundwater pool. Due to the water drop and open head loss<\/p>\n<p>2.the power consumption is more than that of closed towers. Two sets of pumps are needed, which consumes a lot of electricity.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Facilities and equipment<\/strong><\/p>\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" width=\"554\" height=\"633\" src=\"\/wp-content\/uploads\/2023\/12\/d9f25d66967c43a7a00b.jpg\"  class=\"wp-image-3429\" srcset=\"https:\/\/gewabintech.com\/wp-content\/uploads\/2023\/12\/d9f25d66967c43a7a00b.jpg 554w, https:\/\/gewabintech.com\/wp-content\/uploads\/2023\/12\/d9f25d66967c43a7a00b-525x600.jpg 525w\" sizes=\"(max-width: 554px) 100vw, 554px\" title=\"Closed Circuit Cooling Towers\u63d2\u56fe1\" alt=\"Closed Circuit Cooling Towers\u63d2\u56fe1\" \/><\/figure>\n<\/div>\n<p>&nbsp;<\/p>\n<p>Hot Tags: closed circuit cooling towers, suppliers, manufacturers, customized, price, Cross Flow Cooling Tower manufacturers, Hybrid Closed Circuit Cooling Tower, Cooling Tower Systems factory, Closed Circuit Cooling Towers, Anti noise Square Cooling Tower, flow tech cooling tower<\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>Introduction Closed circuit&nbsp;Cooling Tower also named Evaporative cooler. It is the type of cooling tower placed the heat exchange tube inner the tower to ensure the cooling effect by circulation of air, spray water and circulating water. &nbsp; Main Components Coil Made of high-quality seamless steel pipes. The coil unit are &nbsp;made by SS-304\/316L stainless steel. Maximum pressure of our coils could reach to 32Mpa. Spray Pump Sealed by top quality rotary no-limited machinery seal, no leaking, long lifecycle, small horse power, large flow volume, low noise and high performance. Fan Axial type;aluminum alloy propeller Casing SS-304\/316L or imported Aluminum-zinc alloy plate,&nbsp;Mg-Al-zinc plate Electric Water Treatment Device Clear the circuit water, effectively avoid the scale forming on the surface of coils and PVC fills. Removable Drift Eliminator PVC material; Make sure that the water loss rate will be less than 0.002% Cooling Tower Fill 100% Original Material PVC Infill, special design with great cooling effect &nbsp; Closed Water Cooling Tower&nbsp;Advantage 1. Combination Closer approach to wet bulb temperature and reduce fouling improve process efficiency 2. Lower process temperatures ,less required space ,and lower energy consumption. 3. Through Systems Reduces environmental impact ,saving up to 95% of the cooling water . 4. Reduced installed Cost And Space Requirements Effectively combines the function of a cooling tower and heat exchanger into one piece of equipment ,reduce required piping and system complexity. &nbsp; VS open cooling tower Closed circuit cooling tower 1. The whole pipeline system is closed circulation, and the circulating water is distilled water, which can make the vacuum furnace heat exchanger and small pipelines not scale, pollute, or corrode, and almost make the vacuum furnace Double the life. 2. There is almost no water consumption in circulating water. The same type of equipment saves about 7,000 tons of water per year. 3.&nbsp;Low operating costs and low maintenance &nbsp; Open cooling towers 1. It is necessary to excavate 1-2 20 cubic meters of groundwater pool. Due to the water drop and open head loss 2.the power consumption is more than that of closed towers. Two sets of pumps are needed, which consumes a lot of electricity. &nbsp; Facilities and equipment &nbsp; Hot Tags: closed circuit cooling towers, suppliers, manufacturers, customized, price, Cross Flow Cooling Tower manufacturers, Hybrid Closed Circuit Cooling Tower, Cooling Tower Systems factory, Closed Circuit Cooling Towers, Anti noise Square Cooling Tower, flow tech cooling tower &nbsp;<\/p>","protected":false},"author":1,"featured_media":2284,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[47],"tags":[],"acf":[],"_links":{"self":[{"href":"https:\/\/gewabintech.com\/de\/wp-json\/wp\/v2\/posts\/2283"}],"collection":[{"href":"https:\/\/gewabintech.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/gewabintech.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/de\/wp-json\/wp\/v2\/comments?post=2283"}],"version-history":[{"count":5,"href":"https:\/\/gewabintech.com\/de\/wp-json\/wp\/v2\/posts\/2283\/revisions"}],"predecessor-version":[{"id":3948,"href":"https:\/\/gewabintech.com\/de\/wp-json\/wp\/v2\/posts\/2283\/revisions\/3948"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/de\/wp-json\/wp\/v2\/media\/2284"}],"wp:attachment":[{"href":"https:\/\/gewabintech.com\/de\/wp-json\/wp\/v2\/media?parent=2283"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/gewabintech.com\/de\/wp-json\/wp\/v2\/categories?post=2283"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/gewabintech.com\/de\/wp-json\/wp\/v2\/tags?post=2283"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}