{"id":2330,"date":"2023-12-18T09:36:24","date_gmt":"2023-12-18T01:36:24","guid":{"rendered":"http:\/\/gewabin.wangluocloud.com\/?p=2330"},"modified":"2024-08-06T09:34:48","modified_gmt":"2024-08-06T01:34:48","slug":"cooling-towers-and-evaporative-condensers-2","status":"publish","type":"post","link":"https:\/\/gewabintech.com\/es\/products\/closed-circuit-cooling-tower\/cross-flow-cooling-tower\/cooling-towers-and-evaporative-condensers-2\/","title":{"rendered":"Torres de refrigeraci\u00f3n y condensadores evaporativos"},"content":{"rendered":"<p><strong>Introducci\u00f3n<\/strong><\/p>\n<p>Las torres de refrigeraci\u00f3n y los condensadores evaporativos pueden utilizarse en acondicionadores de aire, instrumentaci\u00f3n, hornos el\u00e9ctricos metal\u00fargicos de frecuencia intermedia, convertidores, grupos electr\u00f3genos de centrales el\u00e9ctricas, centrales nucleares de turbina de vapor, subestaciones, industria qu\u00edmica, farmac\u00e9utica, soldadura, aluminio, aceite de refrigeraci\u00f3n de l\u00e1minas de cobre, aceite hidr\u00e1ulico de maquinaria hidr\u00e1ulica de gran tama\u00f1o Utilizados en campos de fabricaci\u00f3n industrial.<\/p>\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" width=\"750\" height=\"647\" src=\"\/wp-content\/uploads\/2024\/01\/4b4561b344359d9ee4b1.jpg\"  class=\"wp-image-2830\" srcset=\"https:\/\/gewabintech.com\/wp-content\/uploads\/2024\/01\/4b4561b344359d9ee4b1.jpg 750w, https:\/\/gewabintech.com\/wp-content\/uploads\/2024\/01\/4b4561b344359d9ee4b1-600x518.jpg 600w\" sizes=\"(max-width: 750px) 100vw, 750px\" title=\"Torres de refrigeraci\u00f3n y condensadores evaporativos\" alt=\"Cooling Towers And Evaporative Condensers\u63d2\u56fe\" \/><\/figure>\n<p>&nbsp;<\/p>\n<p><strong>Par\u00e1metros t\u00e9cnicos<\/strong><\/p>\n<figure class=\"wp-block-table table\">\n<table width=\"100%\" border=\"1\">\n<tbody>\n<tr>\n<td height=\"35\">Componentes principales<\/td>\n<td height=\"35\">&nbsp;<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Bobina del condensador<\/td>\n<td height=\"35\">Fabricado con tubos de acero sin soldadura de alta calidad. La unidad de bobina se hacen por SS-304\/316L acero inoxidable. La presi\u00f3n m\u00e1xima de nuestras bobinas podr\u00eda llegar a 32Mpa.<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Bomba pulverizadora<\/td>\n<td height=\"35\">Sellado mediante junta de maquinaria rotativa no limitada de primera calidad, sin fugas, largo ciclo de vida, peque\u00f1a potencia, gran caudal, bajo ruido y alto rendimiento.<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Ventilador<\/td>\n<td height=\"35\">Tipo axial; h\u00e9lice de aleaci\u00f3n de aluminio<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Carcasa<\/td>\n<td height=\"35\">SS-304\/316L o placa de aleaci\u00f3n de aluminio-cinc importada, placa de Mg-Al-cinc<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Depuradora el\u00e9ctrica<\/td>\n<td height=\"35\">Limpiar el agua del circuito, evitar eficazmente la formaci\u00f3n de incrustaciones en la superficie de las bobinas y los rellenos de PVC.<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Eliminador de deriva extra\u00edble<\/td>\n<td height=\"35\">Material de PVC; Aseg\u00farese de que la tasa de p\u00e9rdida de agua ser\u00e1 inferior a 0,002%<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Llenado de la torre de refrigeraci\u00f3n<\/td>\n<td height=\"35\">100% Material original Relleno de PVC, dise\u00f1o especial con gran efecto refrigerante<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p>&nbsp;<\/p>\n<p><strong>Principio de funcionamiento<\/strong><\/p>\n<p>El agua de la balsa se bombea a la tuber\u00eda colectora, pasa por las boquillas de distribuci\u00f3n y se pulveriza a las tuber\u00edas de la bater\u00eda de intercambio t\u00e9rmico. Se forma una capa de agua uniforme alrededor de la superficie exterior de las tuber\u00edas, el aire fr\u00edo entra en el cuerpo de la torre a trav\u00e9s de la entrada de aire del lateral de la torre y fluye a trav\u00e9s de la capa de agua fuera de las tuber\u00edas del serpent\u00edn en direcciones opuestas a la del agua pulverizada; una parte del agua pulverizada se evapora y absorbe calor del agua del serpent\u00edn. El aire absorbe dicho calor, as\u00ed como la transferencia de calor por contacto, y se convierte en aire h\u00famedo caliente saturado, y luego se descarga a la atm\u00f3sfera desde el ventilador de escape superior, el resto del agua de pulverizaci\u00f3n fluye a la tuber\u00eda colectora en la parte inferior de la torre y se bombea al ciclo de pulverizaci\u00f3n.<\/p>\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" width=\"341\" height=\"245\" src=\"\/wp-content\/uploads\/2024\/01\/c073de86e7dfd38e8672.jpg\"  class=\"wp-image-3323\" title=\"Torres de refrigeraci\u00f3n y condensadores evaporativos\u63d2\u56fe1\" alt=\"Cooling Towers And Evaporative Condensers\u63d2\u56fe1\" \/><\/figure>\n<\/div>\n<p>&nbsp;<\/p>\n<p><strong>Gu\u00eda de selecci\u00f3n<\/strong><\/p>\n<p>1.El caudal de agua de refrigeraci\u00f3n G=m3\/h<\/p>\n<p>2.La temperatura de entrada de la torre de refrigeraci\u00f3n T1=\u2103<\/p>\n<p>3.La temperatura de salida de la torre de refrigeraci\u00f3n T2=\u2103<\/p>\n<p>4.La temperatura de bulbo h\u00famedo de c\u00e1lculo de la ubicaci\u00f3n de la instalaci\u00f3n T=\u2103<\/p>\n<p>C\u00e1lculo del rechazo t\u00e9rmico de una torre de refrigeraci\u00f3n cerrada<\/p>\n<p>Q=1,163xGx(T1-T2)<\/p>\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" width=\"416\" height=\"128\" src=\"\/wp-content\/uploads\/2023\/12\/56f2d9f573f8292a8ffe.jpg\"  class=\"wp-image-3165\" title=\"Torres de refrigeraci\u00f3n y condensadores evaporativos\u63d2\u56fe2\" alt=\"Cooling Towers And Evaporative Condensers\u63d2\u56fe2\" \/><\/figure>\n<\/div>\n<p>&nbsp;<\/p>\n<p><strong>Aplicaci\u00f3n<\/strong><\/p>\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" width=\"410\" height=\"900\" src=\"\/wp-content\/uploads\/2023\/12\/7aa4fb84139ea32e21a5-410x900.jpg\"  class=\"wp-image-3352\" srcset=\"https:\/\/gewabintech.com\/wp-content\/uploads\/2023\/12\/7aa4fb84139ea32e21a5-410x900.jpg 410w, https:\/\/gewabintech.com\/wp-content\/uploads\/2023\/12\/7aa4fb84139ea32e21a5-274x600.jpg 274w, https:\/\/gewabintech.com\/wp-content\/uploads\/2023\/12\/7aa4fb84139ea32e21a5-700x1536.jpg 700w, https:\/\/gewabintech.com\/wp-content\/uploads\/2023\/12\/7aa4fb84139ea32e21a5.jpg 750w\" sizes=\"(max-width: 410px) 100vw, 410px\" title=\"Torres de refrigeraci\u00f3n y condensadores evaporativos\u63d2\u56fe3\" alt=\"Cooling Towers And Evaporative Condensers\u63d2\u56fe3\" \/><\/figure>\n<p>&nbsp;<\/p>\n<p>Hot Tags: torres de refrigeraci\u00f3n y condensadores evaporativos, proveedores, fabricantes, modificado para requisitos particulares, precio, Refrigeraci\u00f3n por agua Evaporativa Fluid Cooler, enfriador evaporativo condensador, Industrial Torre de refrigeraci\u00f3n de f\u00e1brica, de flujo cruzado tipo de torre de refrigeraci\u00f3n, Anti ruido Torre de refrigeraci\u00f3n cuadrada, fluido refrigerador torre de refrigeraci\u00f3n<\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>Introduction Cooling Towers and Evaporative Condensers can be used in air conditioners, instrumentation, metallurgical intermediate frequency electric furnaces, converters, power plant generator sets, steam turbine nuclear power plants, substations, chemical, pharmaceutical, welding, aluminum, copper foil cooling oil, large hydraulic machinery hydraulic oil Used in industrial manufacturing fields. &nbsp; Technical Parameter Main Components &nbsp; Condenser&nbsp;Coil Made of high-quality seamless steel pipes. The coil unit are &nbsp;made by SS-304\/316L stainless steel. Maximum pressure of our coils could reach to 32Mpa. Spray Pump Sealed by top quality rotary no-limited machinery seal, no leaking, long lifecycle, small horse power, large flow volume, low noise and high performance. Fan Axial type;aluminum alloy propeller Casing SS-304\/316L or imported Aluminum-zinc alloy plate,&nbsp;Mg-Al-zinc plate Electric Water Treatment Device Clear the circuit water, effectively avoid the scale forming on the surface of coils and PVC fills. Removable Drift Eliminator PVC material; Make sure that the water loss rate will be less than 0.002% Cooling Tower Fill 100% Original Material PVC Infill, special design with great cooling effect &nbsp; Working Principle The water in the basin is pumped to the collector pipe, goes through distribution nozzles and sprays to heat-exchange coil pipes. An even water layer is formed around the outer surface of the pipes, cold air enters to the tower body through the air inlet of the tower lateral and flow through water layer outside the coil pipes in opposite directions from the spray water; a part of the spray water evaporates and absorbs heat from the water in coil. The air absorbs the said heat as well as heat transfer by contact, and becomes saturated hot humid air, then discharges to the atmosphere from the top exhaust fan, the rest spray water flows to the collector pipe at low part of tower and is pumped to spraying cycle. &nbsp; Selection Guide 1.The cooling water flow&nbsp; G=m3\/h 2.The temperature of inlet cooling tower T1=\u2103 3.The temperature of outlet cooling tower T2=\u2103 4.The calculation wet bulb temperature of installation location T=\u2103 The heat rejection calculation of closed cooling tower Q=1.163xGx(T1-T2) &nbsp; Application &nbsp; Hot Tags: cooling towers and evaporative condensers, suppliers, manufacturers, customized, price, Water Cooling Evaporative Fluid Cooler, evaporative condenser chiller, Industrial Cooling Tower factory, cross flow type cooling tower, Anti noise Square Cooling Tower, fluid cooler cooling tower &nbsp;<\/p>","protected":false},"author":1,"featured_media":2331,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[47],"tags":[],"acf":[],"_links":{"self":[{"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/posts\/2330"}],"collection":[{"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/comments?post=2330"}],"version-history":[{"count":5,"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/posts\/2330\/revisions"}],"predecessor-version":[{"id":3933,"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/posts\/2330\/revisions\/3933"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/media\/2331"}],"wp:attachment":[{"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/media?parent=2330"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/categories?post=2330"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/tags?post=2330"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}