{"id":2350,"date":"2023-12-18T09:42:00","date_gmt":"2023-12-18T01:42:00","guid":{"rendered":"http:\/\/gewabin.wangluocloud.com\/?p=2350"},"modified":"2024-08-06T09:13:26","modified_gmt":"2024-08-06T01:13:26","slug":"cross-flow-cooling-tower-with-closed-circuit","status":"publish","type":"post","link":"https:\/\/gewabintech.com\/es\/products\/closed-circuit-cooling-tower\/cross-flow-cooling-tower\/cross-flow-cooling-tower-with-closed-circuit\/","title":{"rendered":"Torre de refrigeraci\u00f3n de flujo cruzado con circuito cerrado"},"content":{"rendered":"<p><strong>Introducci\u00f3n<\/strong><\/p>\n<p>La torre de refrigeraci\u00f3n de flujo cruzado con circuito cerrado se ha dise\u00f1ado seg\u00fan el principio de flujo cruzado y cuenta con un motor y un ventilador de bajo nivel de ruido. Su dise\u00f1o compacto la hace id\u00f3nea para la refrigeraci\u00f3n de equipos, la refrigeraci\u00f3n de procesos industriales y la climatizaci\u00f3n.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Detalles del producto&nbsp;<\/strong><\/p>\n<p>1. Ventilador axial<\/p>\n<p>Motor antiespecial, clase de protecci\u00f3n IP55, clase de aislamiento F, ventilador axial con aspas de aleaci\u00f3n de aluminio. Arranque directo.<\/p>\n<p>2. Serpentines de condensaci\u00f3n<\/p>\n<p>El material de los tubos del intercambiador de calor es cobre de alta calidad o acero inoxidable SUS 304 o 316L. Se someten a tres pruebas de clasificaci\u00f3n y de presi\u00f3n para garantizar su estanqueidad.<\/p>\n<p>3. 3. Bomba de agua<\/p>\n<p>Utilizamos una bomba especial para torres de refrigeraci\u00f3n, con motor WEG, de tama\u00f1o reducido, peso ligero y dise\u00f1o silencioso. Ofrece un mantenimiento sencillo y una larga vida \u00fatil.<\/p>\n<p>4. Eliminador de gotas<\/p>\n<p>El eliminador de gotas de PVC cambia la direcci\u00f3n del flujo de aire tres veces, reciclando el vapor al m\u00e1ximo para ahorrar agua. Es f\u00e1cil de sustituir.<\/p>\n<p>5. RELLENO DE PVC<\/p>\n<p>Fabricado en PVC, con gran volumen de aire y baja resistencia al viento, evita que los residuos flotantes entren en la torre de refrigeraci\u00f3n cerrada.<\/p>\n<p>6. Sistema de pulverizaci\u00f3n de agua<\/p>\n<p>&nbsp;La boquilla pulverizadora es lo m\u00e1s importante, ya que garantiza que el agua se pulverice de manera uniforme sobre el tubo de intercambio de calor.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Gu\u00eda de selecci\u00f3n<\/strong><\/p>\n<p>GWB&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<\/p>\n<p>Refrigeraci\u00f3n cerrada  Contador N  Modelo (caudal)<\/p>\n<p>modelo de torre    S-cross<\/p>\n<p>1. Caudal de agua de refrigeraci\u00f3n: G = m\u00b3\/h<\/p>\n<p>2. Temperatura de entrada a la torre de refrigeraci\u00f3n T1 = \u2103<\/p>\n<p>3. La temperatura de salida de la torre de refrigeraci\u00f3n T2 = \u2103<\/p>\n<p>4.La temperatura de bulbo h\u00famedo de c\u00e1lculo de la ubicaci\u00f3n de la instalaci\u00f3n T=\u2103<\/p>\n<p>C\u00e1lculo de la disipaci\u00f3n de calor de una torre de refrigeraci\u00f3n cerrada<\/p>\n<p>Q=1,163xGx(T1-T2)<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Ventajas de la empresa<\/strong><\/p>\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" width=\"553\" height=\"304\" src=\"\/wp-content\/uploads\/2023\/12\/8cd55691f6d34a68bc1f.jpg\"  class=\"wp-image-3330\" title=\"Ilustraci\u00f3n de una torre de refrigeraci\u00f3n de flujo cruzado con circuito cerrado\" alt=\"Cross Flow Cooling Tower With Closed Circuit\u63d2\u56fe\" \/><\/figure>\n<p>&nbsp;<\/p>\n<p>1. Jiangsu Gewabin Thermal Energy Technology Co., Ltd. es un fabricante y distribuidor especializado en el sector de la refrigeraci\u00f3n. La empresa est\u00e1 situada en la ciudad de Yixing, en la provincia de Jiangsu (China), y ocupa una superficie de 15 000 metros cuadrados. Cuenta con unas instalaciones de producci\u00f3n completas y un s\u00f3lido equipo t\u00e9cnico.<\/p>\n<p>2. Tambi\u00e9n podemos personalizar los productos seg\u00fan los requisitos del cliente y ofrecer servicios de fabricaci\u00f3n y productos OEM.<\/p>\n<p>3. Los productos de torres de refrigeraci\u00f3n cerradas de Gewabin minimizan el consumo energ\u00e9tico de todo el sistema, ya que ofrecen temperaturas de funcionamiento m\u00e1s bajas que los equipos refrigerados por aire de tama\u00f1o equivalente.<\/p>\n<p>&nbsp;<\/p>\n<p>Palabras clave: torre de refrigeraci\u00f3n de flujo cruzado con circuito cerrado, proveedores, fabricantes, a medida, precio, f\u00e1brica de torres de refrigeraci\u00f3n de flujo cruzado, torre de refrigeraci\u00f3n industrial OEM, torre de refrigeraci\u00f3n cuadrada para tratamiento de aguas, equipo de refrigeraci\u00f3n: torre de refrigeraci\u00f3n cerrada, sistemas de torres de refrigeraci\u00f3n de China, torre de refrigeraci\u00f3n evaporativa cerrada<\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>Introduction The cross flow cooling tower with closed circuit cooling tower has been designed for cross flow type with low noise motor and fan. The compact design is suitable for equipment cooling, Industrial process cooling and air conditioning. &nbsp; Product details&nbsp; 1. Axial Fan Three anti &#8211; special motor, &nbsp;Protection class is IP55, The Insulation class F, Axial fan with the Aluminum alloy blade. Start directly 2. Condensing coils The heat Exchange tube material is high quality copper tube or the SUS 304, 316L tube. grading and pressure test three times to ensure the closeness. 3. Water pump we use the special cooling tower water pump,WEG motor, &nbsp;the small volume, light weight, silent mode design. easy maintenance and long life. 4. Drift eliminator PVC material drift eliminator change the Airflow direction three times, recycling the steam utmost to save water. It is easy replace. 5. PVC FILL PVC material, large air volume, small Wind resistance, can prevent the Floating debris enter the Closed cooling tower. 6. Water Spray system &nbsp;The spray nozzle is most important, it can ensure the water sprayed on heat exchanged tube evenly. &nbsp; Selection Guide GWB&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Closed cooling &nbsp;N-counter &nbsp;Model\uff08flow rate\uff09 tower model &nbsp;&nbsp;&nbsp;S-cross 1.The cooling water flow &nbsp;G=m3\/h 2.Thetempeatue of inlet coling tower T1=\u2103 3.The tempeatue of outlet coling tower T2=\u2103 4.The calculation wet bulb temperature of installation location T=\u2103 The heat rejction calculation od closed cooling tower Q=1.163xGx(T1-T2) &nbsp; Company advantages &nbsp; 1.Jiangsu Gewabin Thermal Energy Technology Co., Ltd. is a manufacturer and trader specializing in the refrigeration industry. The company is located in Yixing City, Jiangsu Province, China, and covers an area of 15,000 square meters. The company has complete production facilities and strong technical force. 2.We can also customize products according to customer requirements, and provide processing services and OEM products. 3.Gewabin&#8217;s closed-cooling tower products minimize the energy consumption of the entire system by providing lower operating temperatures than equivalent-sized air-cooled equipment. &nbsp; Hot Tags: cross flow cooling tower with closed circuit, suppliers, manufacturers, customized, price, Cross Flow Cooling Tower factory, OEM Industrial Cooling Tower, Square Water Teatment Cooling Tower, Cooling Equipment closed cooling tower, China Cooling Tower Systems, Evaporative Closed Cooling Tower &nbsp;<\/p>","protected":false},"author":1,"featured_media":2339,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[47],"tags":[],"acf":[],"_links":{"self":[{"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/posts\/2350"}],"collection":[{"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/comments?post=2350"}],"version-history":[{"count":6,"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/posts\/2350\/revisions"}],"predecessor-version":[{"id":3927,"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/posts\/2350\/revisions\/3927"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/media\/2339"}],"wp:attachment":[{"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/media?parent=2350"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/categories?post=2350"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/tags?post=2350"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}