{"id":2604,"date":"2018-09-25T16:54:12","date_gmt":"2018-09-25T08:54:12","guid":{"rendered":"http:\/\/gewabin.wangluocloud.com\/?p=2604"},"modified":"2023-12-19T16:54:38","modified_gmt":"2023-12-19T08:54:38","slug":"installation-of-closed-type-cooling-tower","status":"publish","type":"post","link":"https:\/\/gewabintech.com\/es\/news\/company-news\/installation-of-closed-type-cooling-tower\/","title":{"rendered":"Instalaci\u00f3n de una torre de refrigeraci\u00f3n de tipo cerrado"},"content":{"rendered":"<ol><li>Selecci\u00f3n de las posiciones de montaje: la torre de refrigeraci\u00f3n de tipo cerrado, apta para su instalaci\u00f3n en un recinto cerrado o en un entorno exterior con buenas condiciones de ventilaci\u00f3n en el interior, En la direcci\u00f3n de salida de aire, el espacio no debe ser inferior a 2,0 m, de modo que, cuando la torre de refrigeraci\u00f3n cerrada est\u00e9 en funcionamiento, el ventilador de refrigeraci\u00f3n pueda expulsar el aire al exterior; en la direcci\u00f3n del viento de entrada al condensador de la m\u00e1quina de agua fr\u00eda, debe haber un espacio de 1,5 a 2 m, para garantizar el funcionamiento normal de la torre de refrigeraci\u00f3n cerrada.<\/li><\/ol>\n\n\n\n<p>Los requisitos de la unidad se establecen en funci\u00f3n de una superficie s\u00f3lida; por lo tanto, la unidad debe disponerse en torno a un determinado espacio de trabajo, con el fin de facilitar su funcionamiento, inspecci\u00f3n y mantenimiento.<\/p>\n\n\n\n<ol start=\"2\"><li>En el caso de una sala de m\u00e1quinas con mala ventilaci\u00f3n, se recomienda instalar un conducto de aire para que el calor generado por la unidad se expulse al exterior.<\/li><li>Instalaci\u00f3n de canales de agua<\/li><\/ol>\n\n\n\n<p>A. El material de instalaci\u00f3n viene determinado por lo siguiente: las torres de refrigeraci\u00f3n cerradas se someten a rigurosas pruebas e inspecciones antes de salir de f\u00e1brica; el usuario solo tiene que colocar el equipo en su sitio seg\u00fan las caracter\u00edsticas del lugar y el plano de planta completo del equipo de calefacci\u00f3n; el personal t\u00e9cnico del usuario debe leer atentamente el \"esquema del sistema de refrigeraci\u00f3n por agua\" del manual del sistema de refrigeraci\u00f3n por agua, y, en funci\u00f3n de la situaci\u00f3n, debe determinar la longitud de las tuber\u00edas de agua, las v\u00e1lvulas de compuerta, los codos, las conexiones activas, las conexiones directas,<\/p>\n\n\n\n<p>Las tes y otros accesorios de tuber\u00eda, as\u00ed como las mangueras y abrazaderas correspondientes, conectan el sistema de tuber\u00edas de circulaci\u00f3n de agua de refrigeraci\u00f3n.<\/p>\n\n\n\n<p>B. El personal t\u00e9cnico del usuario, siguiendo el \"esquema del sistema de refrigeraci\u00f3n por agua\", debe guiar al fontanero en la instalaci\u00f3n de las tuber\u00edas.<\/p>\n\n\n\n<ol start=\"4\"><li>Instalaci\u00f3n de aparatos el\u00e9ctricos: seg\u00fan el \"esquema el\u00e9ctrico\" del circuito de conexi\u00f3n, el cliente solo tiene que conectar la alimentaci\u00f3n el\u00e9ctrica para poder utilizarlos. Se recomienda elegir un di\u00e1metro de tuber\u00eda para la torre de refrigeraci\u00f3n cerrada que sea entre 1,25 y 1,3 veces la corriente total de la torre de refrigeraci\u00f3n cerrada y otros equipos auxiliares, como una bomba de agua, cuando el di\u00e1metro de la tuber\u00eda de la torre de refrigeraci\u00f3n cerrada sea opcional. En el momento de la distribuci\u00f3n de la unidad, los requisitos de tensi\u00f3n de alimentaci\u00f3n son: la tensi\u00f3n nominal \u00b1 10% o menos.<\/li><\/ol>\n\n\n\n<p>Cuando la fluctuaci\u00f3n de tensi\u00f3n supere el rango especificado, no se pondr\u00e1 en marcha la torre de refrigeraci\u00f3n cerrada; de lo contrario, se considerar\u00e1 un funcionamiento inadecuado y los da\u00f1os causados por la empresa no estar\u00e1n cubiertos por el servicio de mantenimiento.<\/p>\n\n\n\n<ol start=\"5\"><li>Enjuaga las tuber\u00edas y a\u00f1ade agua al dep\u00f3sito<\/li><\/ol>\n\n\n\n<p>Tras la instalaci\u00f3n, a\u00f1ada la cantidad adecuada de agua del grifo, abra la l\u00ednea de purga de la bomba, util\u00edcelo unos d\u00edas y, a continuaci\u00f3n, vac\u00ede el agua del grifo y llene el dep\u00f3sito (500 kg o 1000 kg) con agua blanda (o destilada) para su uso habitual.<\/p>\n\n\n\n<ol start=\"6\"><li>Llenar el dep\u00f3sito de pulverizaci\u00f3n con agua. Tras la instalaci\u00f3n, hay que a\u00f1adir agua del grifo al lavabo de pulverizaci\u00f3n, hasta alcanzar aproximadamente los 2\/3 del volumen total (o ajustar autom\u00e1ticamente el recorrido del tubo de acceso para el suministro autom\u00e1tico de agua).<\/li><\/ol>\n\n\n\n<p>Lava el dep\u00f3sito de pulverizaci\u00f3n con regularidad para que no se vea afectado el rendimiento de la pulverizaci\u00f3n.<\/p>","protected":false},"excerpt":{"rendered":"<p>Selection of mounting positions Closed-type cooling tower suitable for installation in the shelter or with the external environment has good ventilation conditions indoors, In the air exhaust direction space must not be less than 2.0m, so that the closed cooling tower in the work of the cooling fan discharged from the air to the outside environment, in the cold water machine side condenser inlet wind direction should be 1.5-2m space, to ensure the normal working environment of closed cooling tower. Unit requirements placed on the basis of a solid level, the unit should be left around a certain working space, in order to facilitate the operation, inspection and maintenance. For the engine room with poor ventilation, it is recommended that the air duct be added, and the heat from the unit will be ejected outdoors. Installation of waterways A. The installation material determines: Closed cooling tower before the factory has been strict testing and inspection, the user just according to the scene and a full set of heating equipment floor plan to put the device in place, by the user technical staff carefully read the water cooling system manual &#8220;water cooling schematic&#8221;, and according to the situation to determine the water pipe length, gate valve, elbow, live connection, direct, Tee and other pipe fittings and the corresponding hoses and hose clamps, connect the cooling water circulating piping system. B. By the user technical personnel according to &#8220;water-cooled schematic diagram&#8221; guide the plumber to install the waterway. Installation of electrical appliances According to &#8220;electrical schematic&#8221; connection circuit, the client only need to direct power to use. It is recommended to choose between 1.25-1.3 times times the total current of the closed cooling tower and other auxiliary equipment, such as a water pump, when the closed cooling tower line diameter is optional. When the unit is distributed, the supply voltage requirements: The rated voltage \u00b1 10% or less. When the voltage fluctuation exceeds the specified range, no starting closed cooling tower, otherwise considered improper operation, the damage caused by the company is not within the scope of maintenance. Rinse the piping and add water to the tank After installation, add the appropriate amount of tap water, open the pump flushing line, use a few days later, and then drain the tap water to fill the box (500kg or 1000kg) soft (or distilled) to normal use. Spray Tank with water After the installation, you need to add tap water to the spray sink, which is about 2\/3 of the total volume (or automatic adjustment of the access tube routing automatic water supply). Wash the spray tank regularly to avoid affecting the spray effect.<\/p>","protected":false},"author":1,"featured_media":2605,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[12],"tags":[],"acf":[],"_links":{"self":[{"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/posts\/2604"}],"collection":[{"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/comments?post=2604"}],"version-history":[{"count":1,"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/posts\/2604\/revisions"}],"predecessor-version":[{"id":2606,"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/posts\/2604\/revisions\/2606"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/media\/2605"}],"wp:attachment":[{"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/media?parent=2604"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/categories?post=2604"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/tags?post=2604"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}