{"id":2621,"date":"2020-06-10T09:24:56","date_gmt":"2020-06-10T01:24:56","guid":{"rendered":"http:\/\/gewabin.wangluocloud.com\/?p=2621"},"modified":"2023-12-20T09:48:31","modified_gmt":"2023-12-20T01:48:31","slug":"xplanation-and-solution-of-common-failures-of-closed-cooling-tower","status":"publish","type":"post","link":"https:\/\/gewabintech.com\/es\/news\/company-news\/xplanation-and-solution-of-common-failures-of-closed-cooling-tower\/","title":{"rendered":"Explicaci\u00f3n y soluci\u00f3n de las aver\u00edas m\u00e1s comunes en las torres de refrigeraci\u00f3n cerradas"},"content":{"rendered":"<p>Las torres de refrigeraci\u00f3n cerradas suelen funcionar al aire libre. En comparaci\u00f3n con los equipos instalados en interiores, la probabilidad de que se produzcan aver\u00edas es mayor. Entonces, \u00bfcu\u00e1les son las aver\u00edas m\u00e1s habituales en el uso de las torres de refrigeraci\u00f3n cerradas y c\u00f3mo debemos actuar ante ellas? Hemos recopilado para todos vosotros las aver\u00edas m\u00e1s comunes y sus soluciones en las torres de refrigeraci\u00f3n cerradas, y esperamos que os sean de ayuda.<\/p>\n\n\n\n<p>Aver\u00edas habituales y soluciones de las torres de refrigeraci\u00f3n cerradas:<\/p>\n\n\n\n<p>1: Temperatura an\u00f3mala del agua en una torre de refrigeraci\u00f3n cerrada<\/p>\n\n\n\n<p>Causas de la aver\u00eda: mala circulaci\u00f3n del agua en la torre, caudal de agua circulante excesivo o insuficiente en la torre y flujo de aire insuficiente por parte del ventilador. En el funcionamiento del sistema de circulaci\u00f3n, la circulaci\u00f3n secundaria del gas caliente es, como m\u00ednimo, fundamental para la temperatura. El radiador y la tuber\u00eda de distribuci\u00f3n de agua se ven afectados de nuevo y deben revisarse uno por uno y solucionarse de inmediato.<\/p>\n\n\n\n<p>Soluci\u00f3n: En primer lugar, comprueba el volumen de agua de la torre para ver si cumple con las especificaciones normales. Un caudal de agua excesivo provocar\u00e1 que la temperatura del agua aumente. En segundo lugar, comprueba si hay madera o aire caliente circulando por el sistema de circulaci\u00f3n y, por \u00faltimo, comprueba el caudal de aire del ventilador. Si el caudal de aire es insuficiente o irregular, las fugas provocar\u00e1n un aumento de la temperatura del agua.<\/p>\n\n\n\n<p>2: El caudal de agua en la torre de refrigeraci\u00f3n desciende r\u00e1pidamente<\/p>\n\n\n\n<p>Causa del fallo: La consecuencia m\u00e1s tangible de la reducci\u00f3n del caudal de agua es una disipaci\u00f3n deficiente del calor por parte del tubo de calor, lo cual ocurre en contadas ocasiones. La causa principal es la obstrucci\u00f3n de los orificios de agua o de los filtros, lo que provoca un suministro insuficiente de agua y, en consecuencia, un consumo cada vez mayor. Si el nivel de agua en el dep\u00f3sito es demasiado bajo, tambi\u00e9n se producir\u00e1 una falta de agua en la torre.<\/p>\n\n\n\n<p>3: Salpica m\u00e1s gotitas de agua:<\/p>\n\n\n\n<p>Causa del fallo: La causa m\u00e1s habitual de este fen\u00f3meno es que la velocidad de rotaci\u00f3n del tubo de distribuci\u00f3n de agua es demasiado elevada, lo que se debe a un control deficiente. Otras causas pueden ser un exceso de agua en el dep\u00f3sito de distribuci\u00f3n, aletas obstruidas o una pieza incorrecta en la gu\u00eda de agua. Desde el punto de vista funcional, el problema de goteo se debe a un exceso de agua en circulaci\u00f3n en la torre.<\/p>\n\n\n\n<p>Soluci\u00f3n: En primer lugar, comprueba el volumen de agua de refrigeraci\u00f3n en la torre de refrigeraci\u00f3n; controla el volumen de agua a tiempo; reduce el volumen de agua en circulaci\u00f3n; ajusta o sustituye el deflector de agua; desatasca las aletas obstruidas a tiempo; y sustituye y limpia los accesorios de la torre de refrigeraci\u00f3n a tiempo.<\/p>","protected":false},"excerpt":{"rendered":"<p>The operating environment of enclosed cooling towers is usually outdoors. Compared with indoor equipment, the possibility of failure is higher. So, what are the common failures of using enclosed cooling towers, and how should we respond? We have summarized the common failures and solutions of closed cooling towers for everyone, and hope to help you. Common failures and solutions of enclosed cooling towers: 1: Abnormal water temperature of closed cooling tower Causes of failure: Poor water circulation in the tower, too much or too little circulating water flow in the tower, and insufficient air flow from the fan. In the process of the circulation system, the secondary circulation of hot gas is at least critical to the temperature. The radiator and water distribution pipe are affected again and must be checked one by one and dealt with immediately. Solution: The first is to query the water volume in the tower to check whether the water volume meets the normal specifications. Excessive water flow will cause the water temperature to rise. Secondly, check whether there is wood and hot air circulating in the circulation system, and finally check the air volume of the fan. If the air volume is insufficient or uneven, sealing will cause the water temperature to rise. 2: The water flow in the cooling tower drops rapidly Cause of failure: The most practical effect of reducing water flow is poor heat dissipation from the heat pipe, which rarely occurs. The key is clogged water holes or filters, resulting in insufficient water supply, resulting in more and more water. If the water level in the water tank is too low, it will also cause insufficient water in the tower. 3: Splash more water droplets: Cause of failure: The most common cause of this phenomenon is that the rotation speed of the water distribution pipe is too fast, which is caused by poor control. Others include too much water in the distribution tank, clogged fins or the wrong part of the water guide. Functionally, the dripping problem is caused by too much circulating water in the tower. Solution: First check the cooling water volume in the cooling tower, control the water volume in time, reduce the circulating water volume, adjust or replace the new water baffle, open the blocked fins in time, and replace and clean the new cooling tower accessories in time.<\/p>","protected":false},"author":1,"featured_media":2622,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[12],"tags":[],"acf":[],"_links":{"self":[{"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/posts\/2621"}],"collection":[{"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/comments?post=2621"}],"version-history":[{"count":2,"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/posts\/2621\/revisions"}],"predecessor-version":[{"id":2624,"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/posts\/2621\/revisions\/2624"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/media\/2622"}],"wp:attachment":[{"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/media?parent=2621"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/categories?post=2621"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/tags?post=2621"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}