{"id":2908,"date":"2022-09-03T14:41:17","date_gmt":"2022-09-03T06:41:17","guid":{"rendered":"http:\/\/gewabin.wangluocloud.com\/?p=2908"},"modified":"2024-01-11T14:47:00","modified_gmt":"2024-01-11T06:47:00","slug":"the-working-principle-and-application-scope-of-closed-cooling-tower","status":"publish","type":"post","link":"https:\/\/gewabintech.com\/es\/knowledge\/the-working-principle-and-application-scope-of-closed-cooling-tower\/","title":{"rendered":"El principio de funcionamiento y el \u00e1mbito de aplicaci\u00f3n de las torres de refrigeraci\u00f3n cerradas"},"content":{"rendered":"<p>A nivel del software del sistema de nebulizaci\u00f3n de agua, el agua de alimentaci\u00f3n y de desag\u00fce se calientan a una temperatura determinada en el equipo de calentamiento, entran en el economizador de la caldera a trav\u00e9s de la tuber\u00eda de alimentaci\u00f3n de agua y, tras un calentamiento adicional, se env\u00edan al tambor, donde se mezclan con el agua de la caldera y, a continuaci\u00f3n, descienden por el tubo de bajada hasta la entrada de la pared de agua del cilindro de la caldera. El agua absorbe la radiaci\u00f3n t\u00e9rmica del horno en el tubo de la pared refrigerada por agua, y la mezcla de agua y vapor llega al tambor a trav\u00e9s del tubo ascendente, donde el agua y el vapor se separan mediante el equipo de separaci\u00f3n de vapor. El vapor de agua saturado extra\u00eddo fluye hacia el intercambiador de calor desde el extremo superior del tambor, donde, tras una nueva reacci\u00f3n endot\u00e9rmica, se convierte en vapor sobrecalentado a 450 \u00b0C y, a continuaci\u00f3n, se env\u00eda al generador de la turbina.<\/p>\n\n\n\n<p>A nivel del software del sistema de encendido y ventilaci\u00f3n de humos, el ventilador env\u00eda el gas al precalentador de aire para calentarlo hasta una temperatura determinada. El carb\u00f3n pulverizado se tritura hasta alcanzar un tama\u00f1o de part\u00edcula determinado en el rascador de escoria, y es transportado por una parte del aire caliente procedente del precalentador de aire y pulverizado en el horno a trav\u00e9s del quemador. La mezcla de carb\u00f3n en bruto y gas inyectada por el quemador se mezcla con el resto del aire caliente del horno y se enciende, liberando una gran cantidad de calor. Tras la ignici\u00f3n, el humo caliente y el polvo fluyen a trav\u00e9s del horno, el sistema de condensaci\u00f3n de escoria, el intercambiador de calor, el economizador de la caldera y el precalentador de aire, en ese orden, y a continuaci\u00f3n pasan por el dispositivo de eliminaci\u00f3n de polvo para eliminar las cenizas y la escoria, tras lo cual son enviados a la chimenea por el ventilador para ser expulsados a la atm\u00f3sfera.<\/p>\n\n\n\n<p>www.gwbrefrigeration.com<\/p>","protected":false},"excerpt":{"rendered":"<p>At the software level of the water mist system, the water supply and drainage are heated to a certain temperature in the heating equipment, enter the boiler economizer through the water supply pipeline, and then be sent to the drum after further heating, mixed with the boiler water, and then descended along the lowering pipe to the water wall inlet boiler cylinder. The water digests and absorbs the heat radiation of the furnace in the water-cooled wall tube, and the carbonated beverage mixed material reaches the drum through the riser, and the water and steam are separated by the carbonated beverage separation equipment. The extracted saturated water vapor flows into the heat exchanger from the upper end of the drum, and again endothermic reaction becomes superheated steam at 450\u00b0C, and then sent to the turbine generator. At the software level of the ignition and smoke ventilation system, the fan sends the gas into the air preheater to heat it to a certain temperature. The pulverized coal is ground into a certain particle size in the slag scraper, and is carried by a part of the hot air from the air preheater and sprayed into the furnace through the burner. The raw coal and gas mixture injected by the burner is mixed with other hot air in the furnace and ignited, releasing a large amount of heat. After ignition, the hot smoke and dust flow through the furnace, slag condensing management, heat exchanger, boiler economizer and air preheater in sequence, and then pass through the dust removal device to remove the ash and slag, and then be sent to the chimney by the fan to be discharged to the air. www.gwbrefrigeration.com<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[13],"tags":[],"acf":[],"_links":{"self":[{"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/posts\/2908"}],"collection":[{"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/comments?post=2908"}],"version-history":[{"count":1,"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/posts\/2908\/revisions"}],"predecessor-version":[{"id":2909,"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/posts\/2908\/revisions\/2909"}],"wp:attachment":[{"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/media?parent=2908"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/categories?post=2908"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/gewabintech.com\/es\/wp-json\/wp\/v2\/tags?post=2908"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}