{"id":2275,"date":"2026-02-24T09:10:27","date_gmt":"2026-02-24T01:10:27","guid":{"rendered":"http:\/\/gewabin.wangluocloud.com\/?p=2275"},"modified":"2026-05-27T13:24:12","modified_gmt":"2026-05-27T05:24:12","slug":"anti-noise-square-cooling-tower","status":"publish","type":"post","link":"https:\/\/gewabintech.com\/fr\/products\/closed-circuit-cooling-tower\/cross-flow-cooling-tower\/anti-noise-square-cooling-tower\/","title":{"rendered":"Tour de refroidissement carr\u00e9e antibruit"},"content":{"rendered":"<p><strong>Anti-noise Square Cooling Tower compare to open cooling tower:<\/strong><\/p>\n<p>1. Cela permet d'\u00e9viter que le fluide ne soit contamin\u00e9.<\/p>\n<p>2. Le fluide circule le long du serpentin sans entrer en contact avec l'air ext\u00e9rieur, ce qui permet de r\u00e9duire la formation d'entartrage \u00e0 l'int\u00e9rieur et d'am\u00e9liorer l'efficacit\u00e9 du syst\u00e8me.<\/p>\n<p>3. Cela permet de r\u00e9duire les co\u00fbts \u00e9nerg\u00e9tiques et les frais d'entretien du syst\u00e8me.<\/p>\n<p>4. Cela garantit le bon fonctionnement du syst\u00e8me \u00e0 tout moment.<\/p>\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" width=\"750\" height=\"647\" class=\"wp-image-2830\" src=\"\/wp-content\/uploads\/2024\/01\/4b4561b344359d9ee4b1.jpg\"  srcset=\"https:\/\/gewabintech.com\/wp-content\/uploads\/2024\/01\/4b4561b344359d9ee4b1.jpg 750w, https:\/\/gewabintech.com\/wp-content\/uploads\/2024\/01\/4b4561b344359d9ee4b1-600x518.jpg 600w\" sizes=\"(max-width: 750px) 100vw, 750px\" title=\"Anti-Noise Square Cooling Tower\u63d2\u56fe\" alt=\"Anti-Noise Square Cooling Tower\u63d2\u56fe\" \/><\/figure>\n<p>&nbsp;<\/p>\n<p><strong>Structure and main parts of\u00a0Anti-noise Square Cooling Tower<\/strong><\/p>\n<p><strong>1. Serpentin de condensation<\/strong><\/p>\n<p>1) Made of high-quality seamless steel pipes. The coil unit are \u00a0made by SS-304\/316L stainless steel. Maximum pressure of our coils could reach to 32Mpa.<\/p>\n<p>2) La disposition sp\u00e9ciale des tubes garantit un encombrement r\u00e9duit et un taux d'\u00e9change thermique \u00e9lev\u00e9. Tous les tubes sont test\u00e9s \u00e0 une pression d'air de 2,5 MPa.<\/p>\n<p>3) Un tube ovale sp\u00e9cial assure un meilleur contact de l'eau avec la surface ext\u00e9rieure des tubes<\/p>\n<p><strong>2. Ventilateur axial<\/strong><\/p>\n<p>1) Faible niveau sonore et d\u00e9bit d'air \u00e9lev\u00e9<\/p>\n<p>2) Lames en alliage d'aluminium<\/p>\n<p>3) Moteur r\u00e9sistant \u00e0 l'humidit\u00e9<\/p>\n<p>4) Construction robuste moul\u00e9e d'un seul tenant<\/p>\n<p><strong>3. Pompe \u00e0 eau<\/strong><\/p>\n<p>1) Faible niveau sonore et d\u00e9bit d'eau \u00e9lev\u00e9<\/p>\n<p>2) Indice de protection IP55, classe d'isolation F<\/p>\n<p>3) Fonctionnement sans probl\u00e8me<\/p>\n<p><strong>4. R\u00e9seau de distribution d'eau<\/strong><\/p>\n<p>GWB cooling water <a href=\"https:\/\/www.benigala.com\/\"><strong>Diyarbak\u0131r Escort<\/strong> <\/a>spray system adopts large discharge and anti-blockage nozzles,which can ensure the cooling water furthest <a href=\"https:\/\/www.benigala.com\/\"><strong>Escorte Diyarbak\u0131r<\/strong><\/a> contact the condensing coil and hence overcome the fouling <a href=\"https:\/\/www.benigala.com\/\"><strong>Diyarbak\u0131r Escort Bayan<\/strong><\/a> and promote the moisture to vaporize,thus improve the effect of heat transfer.<\/p>\n<p><strong>5. Removable Drift Eliminator<\/strong><br \/>\n1) Mat\u00e9riau : PVC r\u00e9sistant \u00e0 la corrosion, sp\u00e9cialement con\u00e7u \u00e0 cet effet<br \/>\n2) Avantage : \u00e9limine efficacement l'humidit\u00e9 de l'air. Il est facile \u00e0 d\u00e9monter.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Principales caract\u00e9ristiques<\/strong><\/p>\n<p><strong>1. Excellent Heat Exchange Performance<\/strong><\/p>\n<p>the cooling tower adopt the technology of the combination of coil and stuffing to avoid the dry spot and dirt formed on the coils. so the performance of the heat exchanger is dramatically effective.<\/p>\n<p><strong>2. Convenient Maintenance<\/strong><\/p>\n<p>the cooling tower is designed with access door and reparing ladder. It is easy for technicains to inspect the working condition of the cooling tower.Technicians can enter into the cooling tower during operation time.<\/p>\n<p><strong>3. Convenient Transportation and Installation<\/strong><\/p>\n<p>The cooling tower is designed to be standard upper body part and bottom body part,. It is easy for the transportation and installation of the cooling tower<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Candidature<\/strong><\/p>\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" width=\"399\" height=\"245\" class=\"wp-image-3119\" src=\"\/wp-content\/uploads\/2023\/12\/6296dacf59a638ee8678.jpg\" title=\"Anti-Noise Square Cooling Tower\u63d2\u56fe1\" alt=\"Anti-Noise Square Cooling Tower\u63d2\u56fe1\" \/><\/figure>\n<\/div>\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" width=\"385\" height=\"241\" class=\"wp-image-3120\" src=\"\/wp-content\/uploads\/2023\/12\/80987e9403b3eabefdc5.jpg\" title=\"Anti-Noise Square Cooling Tower\u63d2\u56fe2\" alt=\"Anti-Noise Square Cooling Tower\u63d2\u56fe2\" \/><\/figure>\n<\/div>\n<p>&nbsp;<\/p>\n<p>La tour de refroidissement \u00e0 circuit ferm\u00e9 convient \u00e0 divers types de syst\u00e8mes de refroidissement exigeant une eau de circulation de haute qualit\u00e9 ; elle est largement utilis\u00e9e dans les secteurs de l'\u00e9lectricit\u00e9, de l'industrie chimique, de l'agroalimentaire et dans de nombreux autres secteurs industriels.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Product Case<\/strong><\/p>\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" width=\"665\" height=\"665\" class=\"wp-image-3449\" src=\"\/wp-content\/uploads\/2023\/12\/c9cddd2c8c3ec78ad9b3.jpg\"  srcset=\"https:\/\/gewabintech.com\/wp-content\/uploads\/2023\/12\/c9cddd2c8c3ec78ad9b3.jpg 665w, https:\/\/gewabintech.com\/wp-content\/uploads\/2023\/12\/c9cddd2c8c3ec78ad9b3-600x600.jpg 600w, https:\/\/gewabintech.com\/wp-content\/uploads\/2023\/12\/c9cddd2c8c3ec78ad9b3-150x150.jpg 150w\" sizes=\"(max-width: 665px) 100vw, 665px\" title=\"Anti-Noise Square Cooling Tower\u63d2\u56fe3\" alt=\"Anti-Noise Square Cooling Tower\u63d2\u56fe3\" \/><\/figure>\n<\/div>\n<p>&nbsp;<\/p>\n<p>Hot Tags: anti-noise square cooling tower, suppliers, manufacturers, customized, price, Cooling Towers and Evaporative Condensers, Cooling Tower Systems factory, China Cross Flow Cooling Tower, Cooling Tower Air Conditioning System, China Industrial cooling towers, Cooling Towers and Evaporative Condensers pric<\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>Anti-noise Square Cooling Tower compare to open cooling tower: 1. It can avoid the the fluid from being polluted. 2.The fluid flows along the coil and will not meet outside air, so it will reduce scaling inside and improve the system effectiveness. 3.It reduces the system energy cost and maintenance cost. 4.It assures that the system can run smoothly all the time. &nbsp; Structure and main parts of\u00a0Anti-noise Square Cooling Tower 1.Condensing Coil 1) Made of high-quality seamless steel pipes. The coil unit are \u00a0made by SS-304\/316L stainless steel. Maximum pressure of our coils could reach to 32Mpa. 2) Special tube arrangement ensure a smarter size and high heat-exchange rate. All tubes are tested at 2.5MPa air pressure 3)Special oval tube ensure a better contacting of water on the outer surface of the tubes 2.Axial Fan 1) Low noise with large air-flow 2) Aluminum alloy blades 3) Damp-proof motor 4) One piece molded heavy duty construction 3.Water Pump 1)Low noise &amp; Large water flow 2)Protection level IP55, Insulation level F 3)Trouble-free operation 4.Water Distribution System GWB cooling water Diyarbak\u0131r Escort spray system adopts large discharge and anti-blockage nozzles,which can ensure the cooling water furthest Escort Diyarbak\u0131r contact the condensing coil and hence overcome the fouling Diyarbak\u0131r Escort Bayan and promote the moisture to vaporize,thus improve the effect of heat transfer. 5. Removable Drift Eliminator 1)Material:specially designed non-corroding PVC 2)Advantage:remove moisture effectively from the moist air .It ia convenient to disassemble. &nbsp; Main features 1. Excellent Heat Exchange Performance the cooling tower adopt the technology of the combination of coil and stuffing to avoid the dry spot and dirt formed on the coils. so the performance of the heat exchanger is dramatically effective. 2. Convenient Maintenance the cooling tower is designed with access door and reparing ladder. It is easy for technicains to inspect the working condition of the cooling tower.Technicians can enter into the cooling tower during operation time. 3. Convenient Transportation and Installation The cooling tower is designed to be standard upper body part and bottom body part,. It is easy for the transportation and installation of the cooling tower &nbsp; Application &nbsp; Closed circuit cooling tower is suitable for various kinds of cooling systems with high quality requirements of circulation water, widely used in electric power,chemical industry, food and many other industrial sectors. &nbsp; Product Case &nbsp; Hot Tags: anti-noise square cooling tower, suppliers, manufacturers, customized, price, Cooling Towers and Evaporative Condensers, Cooling Tower Systems factory, China Cross Flow Cooling Tower, Cooling Tower Air Conditioning System, China Industrial cooling towers, Cooling Towers and Evaporative Condensers pric &nbsp;<\/p>","protected":false},"author":1,"featured_media":2268,"comment_status":"open","ping_status":"open","sticky":true,"template":"","format":"standard","meta":[],"categories":[47],"tags":[],"acf":[],"_links":{"self":[{"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/posts\/2275"}],"collection":[{"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/comments?post=2275"}],"version-history":[{"count":3,"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/posts\/2275\/revisions"}],"predecessor-version":[{"id":5815,"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/posts\/2275\/revisions\/5815"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/media\/2268"}],"wp:attachment":[{"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/media?parent=2275"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/categories?post=2275"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/tags?post=2275"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}