{"id":2283,"date":"2023-12-18T09:19:27","date_gmt":"2023-12-18T01:19:27","guid":{"rendered":"http:\/\/gewabin.wangluocloud.com\/?p=2283"},"modified":"2024-08-06T10:29:51","modified_gmt":"2024-08-06T02:29:51","slug":"closed-circuit-cooling-towers","status":"publish","type":"post","link":"https:\/\/gewabintech.com\/fr\/products\/closed-circuit-cooling-tower\/cross-flow-cooling-tower\/closed-circuit-cooling-towers\/","title":{"rendered":"Tours de refroidissement en circuit ferm\u00e9"},"content":{"rendered":"<p><strong>Introduction<\/strong><\/p>\n<p>Closed circuit&nbsp;Cooling Tower also named Evaporative cooler. It is the type of cooling tower placed the heat exchange tube inner the tower to ensure the cooling effect by circulation of air, spray water and circulating water.<\/p>\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" width=\"554\" height=\"554\" src=\"\/wp-content\/uploads\/2023\/12\/cbcad3dddc2ccdffd39f.jpg\"  class=\"wp-image-3428\" srcset=\"https:\/\/gewabintech.com\/wp-content\/uploads\/2023\/12\/cbcad3dddc2ccdffd39f.jpg 554w, https:\/\/gewabintech.com\/wp-content\/uploads\/2023\/12\/cbcad3dddc2ccdffd39f-150x150.jpg 150w\" sizes=\"(max-width: 554px) 100vw, 554px\" title=\"Closed Circuit Cooling Towers\u63d2\u56fe\" alt=\"Closed Circuit Cooling Towers\u63d2\u56fe\" \/><\/figure>\n<\/div>\n<p>&nbsp;<\/p>\n<table class=\"table\" border=\"1\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"2\" rowspan=\"1\" height=\"35\"><strong>Principaux composants<\/strong><\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Bobine<\/td>\n<td height=\"35\">Fabriqu\u00e9s \u00e0 partir de tubes en acier sans soudure de haute qualit\u00e9. Les serpentins sont fabriqu\u00e9s en acier inoxydable SS-304\/316L. La pression maximale de nos serpentins peut atteindre 32 MPa.<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Pompe de pulv\u00e9risation<\/td>\n<td height=\"35\">\u00c9quip\u00e9 d'un joint rotatif de haute qualit\u00e9 sans limite, il ne pr\u00e9sente aucune fuite, offre une longue dur\u00e9e de vie, une faible puissance, un d\u00e9bit \u00e9lev\u00e9, un faible niveau sonore et des performances \u00e9lev\u00e9es.<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Fan<\/td>\n<td height=\"35\">Type axial ; h\u00e9lice en alliage d'aluminium<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Bo\u00eetier<\/td>\n<td height=\"35\">T\u00f4les en acier inoxydable SS-304\/316L ou en alliage aluminium-zinc import\u00e9es, t\u00f4les en alliage magn\u00e9sium-aluminium-zinc<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Appareil \u00e9lectrique de traitement de l'eau<\/td>\n<td height=\"35\">\u00c9liminez l'eau du circuit afin d'emp\u00eacher efficacement la formation de tartre \u00e0 la surface des serpentins et des \u00e9l\u00e9ments de remplissage en PVC.<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">\u00c9liminateur de gouttelettes amovible<\/td>\n<td height=\"35\">Mat\u00e9riau PVC ; assurez-vous que le taux de perte d'eau soit inf\u00e9rieur \u00e0 0,002%<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Remplissage de tour de refroidissement<\/td>\n<td style=\"word-break: break-all;\" height=\"35\">100% : mat\u00e9riau d'origine en PVC, conception sp\u00e9ciale offrant un excellent effet rafra\u00eechissant<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><strong>Closed Water Cooling Tower&nbsp;Advantage<\/strong><\/p>\n<p>1. Une approche combin\u00e9e visant \u00e0 se rapprocher de la temp\u00e9rature du bulbe humide et \u00e0 r\u00e9duire l'encrassement permet d'am\u00e9liorer l'efficacit\u00e9 du proc\u00e9d\u00e9<\/p>\n<p>2. Des temp\u00e9ratures de traitement plus basses, un encombrement r\u00e9duit et une consommation d'\u00e9nergie moindre.<\/p>\n<p>3. Ce syst\u00e8me permet de r\u00e9duire l'impact environnemental et d'\u00e9conomiser jusqu'\u00e0 951 TP3T d'eau de refroidissement. .<\/p>\n<p>4. R\u00e9duction des co\u00fbts d'installation et de l'encombrement : ce syst\u00e8me combine efficacement les fonctions d'une tour de refroidissement et d'un \u00e9changeur de chaleur en un seul \u00e9quipement, ce qui permet de r\u00e9duire les besoins en tuyauterie et la complexit\u00e9 du syst\u00e8me.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>VS open cooling tower<\/strong><\/p>\n<p><strong>Closed circuit cooling tower<\/strong><\/p>\n<p>1. The whole pipeline system is closed circulation, and the circulating water is distilled water, which can make the vacuum furnace heat exchanger and small pipelines not scale, pollute, or corrode, and almost make the vacuum furnace Double the life.<\/p>\n<p>2. There is almost no water consumption in circulating water. The same type of equipment saves about 7,000 tons of water per year.<\/p>\n<p>3.&nbsp;Low operating costs and low maintenance<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Open cooling towers<\/strong><\/p>\n<p>1. It is necessary to excavate 1-2 20 cubic meters of groundwater pool. Due to the water drop and open head loss<\/p>\n<p>2.the power consumption is more than that of closed towers. Two sets of pumps are needed, which consumes a lot of electricity.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Installations et \u00e9quipements<\/strong><\/p>\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" width=\"554\" height=\"633\" src=\"\/wp-content\/uploads\/2023\/12\/d9f25d66967c43a7a00b.jpg\"  class=\"wp-image-3429\" srcset=\"https:\/\/gewabintech.com\/wp-content\/uploads\/2023\/12\/d9f25d66967c43a7a00b.jpg 554w, https:\/\/gewabintech.com\/wp-content\/uploads\/2023\/12\/d9f25d66967c43a7a00b-525x600.jpg 525w\" sizes=\"(max-width: 554px) 100vw, 554px\" title=\"Closed Circuit Cooling Towers\u63d2\u56fe1\" alt=\"Closed Circuit Cooling Towers\u63d2\u56fe1\" \/><\/figure>\n<\/div>\n<p>&nbsp;<\/p>\n<p>Hot Tags: closed circuit cooling towers, suppliers, manufacturers, customized, price, Cross Flow Cooling Tower manufacturers, Hybrid Closed Circuit Cooling Tower, Cooling Tower Systems factory, Closed Circuit Cooling Towers, Anti noise Square Cooling Tower, flow tech cooling tower<\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>Introduction Closed circuit&nbsp;Cooling Tower also named Evaporative cooler. It is the type of cooling tower placed the heat exchange tube inner the tower to ensure the cooling effect by circulation of air, spray water and circulating water. &nbsp; Main Components Coil Made of high-quality seamless steel pipes. The coil unit are &nbsp;made by SS-304\/316L stainless steel. Maximum pressure of our coils could reach to 32Mpa. Spray Pump Sealed by top quality rotary no-limited machinery seal, no leaking, long lifecycle, small horse power, large flow volume, low noise and high performance. Fan Axial type;aluminum alloy propeller Casing SS-304\/316L or imported Aluminum-zinc alloy plate,&nbsp;Mg-Al-zinc plate Electric Water Treatment Device Clear the circuit water, effectively avoid the scale forming on the surface of coils and PVC fills. Removable Drift Eliminator PVC material; Make sure that the water loss rate will be less than 0.002% Cooling Tower Fill 100% Original Material PVC Infill, special design with great cooling effect &nbsp; Closed Water Cooling Tower&nbsp;Advantage 1. Combination Closer approach to wet bulb temperature and reduce fouling improve process efficiency 2. Lower process temperatures ,less required space ,and lower energy consumption. 3. Through Systems Reduces environmental impact ,saving up to 95% of the cooling water . 4. Reduced installed Cost And Space Requirements Effectively combines the function of a cooling tower and heat exchanger into one piece of equipment ,reduce required piping and system complexity. &nbsp; VS open cooling tower Closed circuit cooling tower 1. The whole pipeline system is closed circulation, and the circulating water is distilled water, which can make the vacuum furnace heat exchanger and small pipelines not scale, pollute, or corrode, and almost make the vacuum furnace Double the life. 2. There is almost no water consumption in circulating water. The same type of equipment saves about 7,000 tons of water per year. 3.&nbsp;Low operating costs and low maintenance &nbsp; Open cooling towers 1. It is necessary to excavate 1-2 20 cubic meters of groundwater pool. Due to the water drop and open head loss 2.the power consumption is more than that of closed towers. Two sets of pumps are needed, which consumes a lot of electricity. &nbsp; Facilities and equipment &nbsp; Hot Tags: closed circuit cooling towers, suppliers, manufacturers, customized, price, Cross Flow Cooling Tower manufacturers, Hybrid Closed Circuit Cooling Tower, Cooling Tower Systems factory, Closed Circuit Cooling Towers, Anti noise Square Cooling Tower, flow tech cooling tower &nbsp;<\/p>","protected":false},"author":1,"featured_media":2284,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[47],"tags":[],"acf":[],"_links":{"self":[{"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/posts\/2283"}],"collection":[{"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/comments?post=2283"}],"version-history":[{"count":5,"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/posts\/2283\/revisions"}],"predecessor-version":[{"id":3948,"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/posts\/2283\/revisions\/3948"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/media\/2284"}],"wp:attachment":[{"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/media?parent=2283"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/categories?post=2283"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/tags?post=2283"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}