{"id":2330,"date":"2023-12-18T09:36:24","date_gmt":"2023-12-18T01:36:24","guid":{"rendered":"http:\/\/gewabin.wangluocloud.com\/?p=2330"},"modified":"2024-08-06T09:34:48","modified_gmt":"2024-08-06T01:34:48","slug":"cooling-towers-and-evaporative-condensers-2","status":"publish","type":"post","link":"https:\/\/gewabintech.com\/fr\/products\/closed-circuit-cooling-tower\/cross-flow-cooling-tower\/cooling-towers-and-evaporative-condensers-2\/","title":{"rendered":"Tours de refroidissement et condenseurs \u00e9vaporatifs"},"content":{"rendered":"<p><strong>Introduction<\/strong><\/p>\n<p>Cooling Towers and Evaporative Condensers can be used in air conditioners, instrumentation, metallurgical intermediate frequency electric furnaces, converters, power plant generator sets, steam turbine nuclear power plants, substations, chemical, pharmaceutical, welding, aluminum, copper foil cooling oil, large hydraulic machinery hydraulic oil Used in industrial manufacturing fields.<\/p>\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" width=\"750\" height=\"647\" src=\"\/wp-content\/uploads\/2024\/01\/4b4561b344359d9ee4b1.jpg\"  class=\"wp-image-2830\" srcset=\"https:\/\/gewabintech.com\/wp-content\/uploads\/2024\/01\/4b4561b344359d9ee4b1.jpg 750w, https:\/\/gewabintech.com\/wp-content\/uploads\/2024\/01\/4b4561b344359d9ee4b1-600x518.jpg 600w\" sizes=\"(max-width: 750px) 100vw, 750px\" title=\"Cooling Towers And Evaporative Condensers\u63d2\u56fe\" alt=\"Cooling Towers And Evaporative Condensers\u63d2\u56fe\" \/><\/figure>\n<p>&nbsp;<\/p>\n<p><strong>Technical Parameter<\/strong><\/p>\n<figure class=\"wp-block-table table\">\n<table width=\"100%\" border=\"1\">\n<tbody>\n<tr>\n<td height=\"35\">Principaux composants<\/td>\n<td height=\"35\">&nbsp;<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Condenser&nbsp;Coil<\/td>\n<td height=\"35\">Fabriqu\u00e9s \u00e0 partir de tubes en acier sans soudure de haute qualit\u00e9. Les serpentins sont fabriqu\u00e9s en acier inoxydable SS-304\/316L. La pression maximale de nos serpentins peut atteindre 32 MPa.<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Pompe de pulv\u00e9risation<\/td>\n<td height=\"35\">\u00c9quip\u00e9 d'un joint rotatif de haute qualit\u00e9 sans limite, il ne pr\u00e9sente aucune fuite, offre une longue dur\u00e9e de vie, une faible puissance, un d\u00e9bit \u00e9lev\u00e9, un faible niveau sonore et des performances \u00e9lev\u00e9es.<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Fan<\/td>\n<td height=\"35\">Type axial ; h\u00e9lice en alliage d'aluminium<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Bo\u00eetier<\/td>\n<td height=\"35\">T\u00f4les en acier inoxydable SS-304\/316L ou en alliage aluminium-zinc import\u00e9es, t\u00f4les en alliage magn\u00e9sium-aluminium-zinc<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Appareil \u00e9lectrique de traitement de l'eau<\/td>\n<td height=\"35\">\u00c9liminez l'eau du circuit afin d'emp\u00eacher efficacement la formation de tartre \u00e0 la surface des serpentins et des \u00e9l\u00e9ments de remplissage en PVC.<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">\u00c9liminateur de gouttelettes amovible<\/td>\n<td height=\"35\">Mat\u00e9riau PVC ; assurez-vous que le taux de perte d'eau soit inf\u00e9rieur \u00e0 0,002%<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Remplissage de tour de refroidissement<\/td>\n<td height=\"35\">100% : mat\u00e9riau d'origine en PVC, conception sp\u00e9ciale offrant un excellent effet rafra\u00eechissant<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p>&nbsp;<\/p>\n<p><strong>Working Principle<\/strong><\/p>\n<p>L'eau contenue dans le bassin est pomp\u00e9e vers le tuyau collecteur, passe par des buses de distribution et est pulv\u00e9ris\u00e9e sur les tubes du serpentin d'\u00e9change thermique. Une couche d\u2019eau homog\u00e8ne se forme autour de la surface ext\u00e9rieure des tubes ; l\u2019air froid p\u00e9n\u00e8tre dans le corps de la tour par l\u2019entr\u00e9e d\u2019air situ\u00e9e sur le c\u00f4t\u00e9 de celle-ci et circule \u00e0 travers la couche d\u2019eau \u00e0 l\u2019ext\u00e9rieur des tubes du serpentin, dans des directions oppos\u00e9es \u00e0 celles de l\u2019eau pulv\u00e9ris\u00e9e ; une partie de l\u2019eau pulv\u00e9ris\u00e9e s\u2019\u00e9vapore et absorbe la chaleur de l\u2019eau contenue dans le serpentin. L\u2019air absorbe cette chaleur ainsi que celle transmise par contact, et se transforme en air chaud et humide satur\u00e9, avant d\u2019\u00eatre \u00e9vacu\u00e9 dans l\u2019atmosph\u00e8re par le ventilateur d\u2019extraction situ\u00e9 au sommet ; le reste de l\u2019eau pulv\u00e9ris\u00e9e s\u2019\u00e9coule vers le tuyau collecteur situ\u00e9 dans la partie basse de la tour et est pomp\u00e9 pour r\u00e9int\u00e9grer le cycle de pulv\u00e9risation.<\/p>\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" width=\"341\" height=\"245\" src=\"\/wp-content\/uploads\/2024\/01\/c073de86e7dfd38e8672.jpg\"  class=\"wp-image-3323\" title=\"Cooling Towers And Evaporative Condensers\u63d2\u56fe1\" alt=\"Cooling Towers And Evaporative Condensers\u63d2\u56fe1\" \/><\/figure>\n<\/div>\n<p>&nbsp;<\/p>\n<p><strong>Guide de s\u00e9lection<\/strong><\/p>\n<p>1.The cooling water flow&nbsp; G=m3\/h<\/p>\n<p>2.The temperature of inlet cooling tower T1=\u2103<\/p>\n<p>3. Temp\u00e9rature de sortie de la tour de refroidissement T2 = \u2103<\/p>\n<p>4. Temp\u00e9rature du bulbe humide calcul\u00e9e pour le lieu d'installation : T = \u2103<\/p>\n<p>The heat rejection calculation of closed cooling tower<\/p>\n<p>Q = 1,163 \u00d7 G \u00d7 (T\u2081 \u2013 T\u2082)<\/p>\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" width=\"416\" height=\"128\" src=\"\/wp-content\/uploads\/2023\/12\/56f2d9f573f8292a8ffe.jpg\"  class=\"wp-image-3165\" title=\"Cooling Towers And Evaporative Condensers\u63d2\u56fe2\" alt=\"Cooling Towers And Evaporative Condensers\u63d2\u56fe2\" \/><\/figure>\n<\/div>\n<p>&nbsp;<\/p>\n<p><strong>Candidature<\/strong><\/p>\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" width=\"410\" height=\"900\" src=\"\/wp-content\/uploads\/2023\/12\/7aa4fb84139ea32e21a5-410x900.jpg\"  class=\"wp-image-3352\" srcset=\"https:\/\/gewabintech.com\/wp-content\/uploads\/2023\/12\/7aa4fb84139ea32e21a5-410x900.jpg 410w, https:\/\/gewabintech.com\/wp-content\/uploads\/2023\/12\/7aa4fb84139ea32e21a5-274x600.jpg 274w, https:\/\/gewabintech.com\/wp-content\/uploads\/2023\/12\/7aa4fb84139ea32e21a5-700x1536.jpg 700w, https:\/\/gewabintech.com\/wp-content\/uploads\/2023\/12\/7aa4fb84139ea32e21a5.jpg 750w\" sizes=\"(max-width: 410px) 100vw, 410px\" title=\"Cooling Towers And Evaporative Condensers\u63d2\u56fe3\" alt=\"Cooling Towers And Evaporative Condensers\u63d2\u56fe3\" \/><\/figure>\n<p>&nbsp;<\/p>\n<p>Hot Tags: cooling towers and evaporative condensers, suppliers, manufacturers, customized, price, Water Cooling Evaporative Fluid Cooler, evaporative condenser chiller, Industrial Cooling Tower factory, cross flow type cooling tower, Anti noise Square Cooling Tower, fluid cooler cooling tower<\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>Introduction Cooling Towers and Evaporative Condensers can be used in air conditioners, instrumentation, metallurgical intermediate frequency electric furnaces, converters, power plant generator sets, steam turbine nuclear power plants, substations, chemical, pharmaceutical, welding, aluminum, copper foil cooling oil, large hydraulic machinery hydraulic oil Used in industrial manufacturing fields. &nbsp; Technical Parameter Main Components &nbsp; Condenser&nbsp;Coil Made of high-quality seamless steel pipes. The coil unit are &nbsp;made by SS-304\/316L stainless steel. Maximum pressure of our coils could reach to 32Mpa. Spray Pump Sealed by top quality rotary no-limited machinery seal, no leaking, long lifecycle, small horse power, large flow volume, low noise and high performance. Fan Axial type;aluminum alloy propeller Casing SS-304\/316L or imported Aluminum-zinc alloy plate,&nbsp;Mg-Al-zinc plate Electric Water Treatment Device Clear the circuit water, effectively avoid the scale forming on the surface of coils and PVC fills. Removable Drift Eliminator PVC material; Make sure that the water loss rate will be less than 0.002% Cooling Tower Fill 100% Original Material PVC Infill, special design with great cooling effect &nbsp; Working Principle The water in the basin is pumped to the collector pipe, goes through distribution nozzles and sprays to heat-exchange coil pipes. An even water layer is formed around the outer surface of the pipes, cold air enters to the tower body through the air inlet of the tower lateral and flow through water layer outside the coil pipes in opposite directions from the spray water; a part of the spray water evaporates and absorbs heat from the water in coil. The air absorbs the said heat as well as heat transfer by contact, and becomes saturated hot humid air, then discharges to the atmosphere from the top exhaust fan, the rest spray water flows to the collector pipe at low part of tower and is pumped to spraying cycle. &nbsp; Selection Guide 1.The cooling water flow&nbsp; G=m3\/h 2.The temperature of inlet cooling tower T1=\u2103 3.The temperature of outlet cooling tower T2=\u2103 4.The calculation wet bulb temperature of installation location T=\u2103 The heat rejection calculation of closed cooling tower Q=1.163xGx(T1-T2) &nbsp; Application &nbsp; Hot Tags: cooling towers and evaporative condensers, suppliers, manufacturers, customized, price, Water Cooling Evaporative Fluid Cooler, evaporative condenser chiller, Industrial Cooling Tower factory, cross flow type cooling tower, Anti noise Square Cooling Tower, fluid cooler cooling tower &nbsp;<\/p>","protected":false},"author":1,"featured_media":2331,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[47],"tags":[],"acf":[],"_links":{"self":[{"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/posts\/2330"}],"collection":[{"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/comments?post=2330"}],"version-history":[{"count":5,"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/posts\/2330\/revisions"}],"predecessor-version":[{"id":3933,"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/posts\/2330\/revisions\/3933"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/media\/2331"}],"wp:attachment":[{"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/media?parent=2330"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/categories?post=2330"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/tags?post=2330"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}