{"id":2910,"date":"2022-08-31T14:41:36","date_gmt":"2022-08-31T06:41:36","guid":{"rendered":"http:\/\/gewabin.wangluocloud.com\/?p=2910"},"modified":"2024-01-11T14:46:32","modified_gmt":"2024-01-11T06:46:32","slug":"improve-the-working-efficiency-of-closed-cooling-tower","status":"publish","type":"post","link":"https:\/\/gewabintech.com\/fr\/knowledge\/improve-the-working-efficiency-of-closed-cooling-tower\/","title":{"rendered":"Am\u00e9liorer l'efficacit\u00e9 de fonctionnement d'une tour de refroidissement ferm\u00e9e"},"content":{"rendered":"<p>How to improve the working efficiency of closed cooling tower\uff1f<\/p>\n\n\n\n<p>The closed cooling tower is a new type of cooling equipment, which has a good energy saving effect after natural cooling in winter. The actual closed-circuit cooling energy consumption and the problems existing in the cooling unit provide a reference for the design and use of the closed-circuit cooling tower. For the cooling tower test cooling platform, the cooling performance was modified by changing the inlet temperature and water flow, air quality dry air and wet bulb temperature, and spray water flow. The coefficients are obtained from the mass transfer coefficients of the outside of the convective film and the air. The test results show that the heat transfer coefficient of the water film is the mass flow of the air and the temperature of the sprayed water. This is a test of practical supply. Air mass and water transfer coefficients are functions of air mass flow. The elliptical tube cooling tower with certain guiding function is optimized and planned by using the heat transfer coefficient and the water film mass transfer coefficient. Thus, using this mathematical model, the cooling process of the elliptical tube is simulated through the wall of the supply tube. The linear pressure drop of active heat of the fluid cooler, the simulation and the experimental results of the coil heat exchanger are very close. This new type of closed cooling tower is mainly to study the function test of closed cooling tower. Cross-flow cooling was obtained after testing. These elements are profiled and optimized to optimize the type of interleaved flow. Therefore, the closed cooling tower is one of the cooling equipments commonly used in daily life. The thermal conductivity of the tube wall is an order of magnitude smaller than that of the closed cooling tower, which can be neglected in the calculation. But other thermal resistances cannot be neglected, and there are many factors that affect the total thermal resistance of the coil.<\/p>\n\n\n\n<p>www.gwbrefrigeration.com<\/p>","protected":false},"excerpt":{"rendered":"<p>Comment am\u00e9liorer l'efficacit\u00e9 de fonctionnement d'une tour de refroidissement \u00e0 circuit ferm\u00e9 ? La tour de refroidissement \u00e0 circuit ferm\u00e9 est un nouveau type d'\u00e9quipement de refroidissement qui permet de r\u00e9aliser d'importantes \u00e9conomies d'\u00e9nergie gr\u00e2ce au refroidissement naturel en hiver. La consommation \u00e9nerg\u00e9tique r\u00e9elle du circuit ferm\u00e9 de refroidissement et les probl\u00e8mes rencontr\u00e9s au niveau de l\u2019unit\u00e9 de refroidissement constituent une r\u00e9f\u00e9rence pour la conception et l\u2019utilisation de la tour de refroidissement \u00e0 circuit ferm\u00e9. Pour la plateforme d\u2019essai de la tour de refroidissement, les performances de refroidissement ont \u00e9t\u00e9 modifi\u00e9es en faisant varier la temp\u00e9rature d\u2019entr\u00e9e et le d\u00e9bit d\u2019eau, la qualit\u00e9 de l\u2019air (air sec et temp\u00e9rature au bulbe humide), ainsi que le d\u00e9bit d\u2019eau pulv\u00e9ris\u00e9e. Les coefficients sont obtenus \u00e0 partir des coefficients de transfert de masse entre la surface ext\u00e9rieure du film convectif et l\u2019air. Les r\u00e9sultats des essais montrent que le coefficient de transfert thermique du film d\u2019eau d\u00e9pend du d\u00e9bit massique de l\u2019air et de la temp\u00e9rature de l\u2019eau pulv\u00e9ris\u00e9e. Il s\u2019agit d\u2019un essai d\u2019application pratique. Les coefficients de transfert de masse de l\u2019air et de l\u2019eau sont des fonctions du d\u00e9bit massique d\u2019air. La tour de refroidissement \u00e0 tubes elliptiques dot\u00e9e d\u2019une certaine fonction de guidage est optimis\u00e9e et con\u00e7ue \u00e0 l\u2019aide du coefficient de transfert thermique et du coefficient de transfert de masse du film d\u2019eau. Ainsi, \u00e0 l\u2019aide de ce mod\u00e8le math\u00e9matique, le processus de refroidissement du tube elliptique est simul\u00e9 \u00e0 travers la paroi du tube d\u2019alimentation. La perte de charge lin\u00e9aire li\u00e9e \u00e0 la chaleur active du refroidisseur de fluide, ainsi que les r\u00e9sultats de simulation et les r\u00e9sultats exp\u00e9rimentaux de l\u2019\u00e9changeur de chaleur \u00e0 serpentins, sont tr\u00e8s proches. Ce nouveau type de tour de refroidissement ferm\u00e9e vise principalement \u00e0 \u00e9tudier le test de fonctionnement de ce type d\u2019installation. Un refroidissement \u00e0 flux crois\u00e9s a \u00e9t\u00e9 obtenu \u00e0 l\u2019issue des essais. Ces \u00e9l\u00e9ments ont \u00e9t\u00e9 profil\u00e9s et optimis\u00e9s afin d\u2019optimiser le type d\u2019\u00e9coulement entrelac\u00e9. Par cons\u00e9quent, la tour de refroidissement ferm\u00e9e fait partie des \u00e9quipements de refroidissement couramment utilis\u00e9s dans la vie quotidienne. La conductivit\u00e9 thermique de la paroi du tube est d\u2019un ordre de grandeur inf\u00e9rieure \u00e0 celle de la tour de refroidissement ferm\u00e9e, ce qui permet de la n\u00e9gliger dans le calcul. En revanche, les autres r\u00e9sistances thermiques ne peuvent \u00eatre n\u00e9glig\u00e9es, et de nombreux facteurs influencent la r\u00e9sistance thermique totale du serpentin. www.gwbrefrigeration.com<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[13],"tags":[],"acf":[],"_links":{"self":[{"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/posts\/2910"}],"collection":[{"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/comments?post=2910"}],"version-history":[{"count":1,"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/posts\/2910\/revisions"}],"predecessor-version":[{"id":2911,"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/posts\/2910\/revisions\/2911"}],"wp:attachment":[{"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/media?parent=2910"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/categories?post=2910"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/tags?post=2910"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}