{"id":3031,"date":"2022-03-13T15:26:01","date_gmt":"2022-03-13T07:26:01","guid":{"rendered":"http:\/\/gewabin.wangluocloud.com\/?p=3031"},"modified":"2024-01-12T15:27:35","modified_gmt":"2024-01-12T07:27:35","slug":"tips-for-purchasing-high-quality-closed-cooling-towers","status":"publish","type":"post","link":"https:\/\/gewabintech.com\/fr\/knowledge\/tips-for-purchasing-high-quality-closed-cooling-towers\/","title":{"rendered":"Conseils pour l'achat de tours de refroidissement ferm\u00e9es de haute qualit\u00e9"},"content":{"rendered":"<p>8 Tips for Purchasing High Quality Closed Cooling Towers<\/p>\n\n\n\n<ol><li>The cooling tower shell needs to reach a certain thickness, with high hardness and toughness, good bending strength and good surface gloss. In order to save costs, some cooling tower manufacturers not only choose materials of poor quality, but also the shell is easy to age, crack, and fade, and the thickness and strength of the shell are not good, which greatly shortens the service life of the cooling tower.<\/li><li>The metal frame should be high-quality steel with good bearing capacity and strong corrosion resistance. Therefore, the cooling tower should use high-quality steel of national standard. In addition to stainless steel, it also includes some high-quality steel that is hot-dip galvanized. The galvanized layer is required to be uniform and fine, but the steel used by some cooling tower manufacturers is of poor quality (thin). And the galvanizing treatment is not in place, which makes the shell of the cooling tower easy to be damaged by rust.<\/li><\/ol>\n\n\n\n<p>&nbsp;3. The Closed Circuit Cooling Tower packing should be made of high-quality PVC and other materials with strong anti-ultraviolet and chemical corrosion resistance.<\/p>\n\n\n\n<ol start=\"4\"><li>The motor has high insulation grade, good starting performance and reliable operation. As for the direct-connected cooling tower not equipped with a gearbox, the motor used should be a motor with a higher number of series, which has a lower speed and smooth operation.<\/li><\/ol>\n\n\n\n<ol start=\"5\"><li>The requirements for the fan are: reasonable structure, small wind resistance, large air volume, low noise, light weight and high efficiency.<\/li><li>The cooling capacity is satisfied. The product practice standards of some cooling tower manufacturers do not match the specifications, and the actual volume of the cooling tower is obviously too small, which is a typical cut corners. It is also difficult to achieve a good cooling effect, and the fan speed is too fast, which will not only shorten the service life of the fan and the motor, but also easily cause serious floating water problems.<\/li><li>When selecting the cooling tower, the flow rate should be judged according to the actual needs of the equipment. If it is too small, it will not achieve the expected cooling effect. If it is too large, it will cause unnecessary power waste. Regarding the square cooling tower, in the case of large weight, considering the stability of work and energy saving, it is advisable to use the multi-fan parallel type.<\/li><\/ol>\n\n\n\n<ol start=\"8\"><li>The overall placement of the cooling tower is scientific and reasonable. On the premise of ensuring heat dissipation (cooling), the shape should be circulated, the gloss should be good, the color will not fade, and it should be easy to repair.<\/li><\/ol>\n\n\n\n<p>www.gwbrefrigeration.com<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" width=\"675\" height=\"900\" src=\"http:\/\/gewabin.wangluocloud.com\/wp-content\/uploads\/2024\/01\/1aa37c4e5fe6ec25e24d-675x900.jpg\"  class=\"wp-image-3032\" srcset=\"https:\/\/gewabintech.com\/wp-content\/uploads\/2024\/01\/1aa37c4e5fe6ec25e24d-675x900.jpg 675w, https:\/\/gewabintech.com\/wp-content\/uploads\/2024\/01\/1aa37c4e5fe6ec25e24d-450x600.jpg 450w, https:\/\/gewabintech.com\/wp-content\/uploads\/2024\/01\/1aa37c4e5fe6ec25e24d-768x1024.jpg 768w, https:\/\/gewabintech.com\/wp-content\/uploads\/2024\/01\/1aa37c4e5fe6ec25e24d.jpg 850w\" sizes=\"(max-width: 675px) 100vw, 675px\" title=\"Tips For Purchasing High Quality Closed Cooling Towers\u63d2\u56fe\" alt=\"Tips For Purchasing High Quality Closed Cooling Towers\u63d2\u56fe\" \/><\/figure>","protected":false},"excerpt":{"rendered":"<p>8 conseils pour l'achat de tours de refroidissement ferm\u00e9es de haute qualit\u00e9 : l'enveloppe de la tour de refroidissement doit pr\u00e9senter une \u00e9paisseur suffisante, une duret\u00e9 et une t\u00e9nacit\u00e9 \u00e9lev\u00e9es, une bonne r\u00e9sistance \u00e0 la flexion et un bon brillant de surface. Afin de r\u00e9duire les co\u00fbts, certains fabricants de tours de refroidissement choisissent non seulement des mat\u00e9riaux de mauvaise qualit\u00e9, mais proposent \u00e9galement une enveloppe qui vieillit, se fissure et se d\u00e9colore facilement, et dont l\u2019\u00e9paisseur et la r\u00e9sistance sont insuffisantes, ce qui r\u00e9duit consid\u00e9rablement la dur\u00e9e de vie de la tour de refroidissement. La structure m\u00e9tallique doit \u00eatre en acier de haute qualit\u00e9, offrant une bonne capacit\u00e9 de charge et une forte r\u00e9sistance \u00e0 la corrosion. Par cons\u00e9quent, la tour de refroidissement doit \u00eatre fabriqu\u00e9e \u00e0 partir d\u2019acier de haute qualit\u00e9 conforme aux normes nationales. Outre l\u2019acier inoxydable, cela inclut \u00e9galement certains aciers de haute qualit\u00e9 galvanis\u00e9s \u00e0 chaud. La couche de galvanisation doit \u00eatre uniforme et fine, mais l\u2019acier utilis\u00e9 par certains fabricants de tours de refroidissement est de mauvaise qualit\u00e9 (trop mince). De plus, le traitement de galvanisation n\u2019est pas effectu\u00e9 correctement, ce qui rend l\u2019enveloppe de la tour de refroidissement vuln\u00e9rable \u00e0 la rouille.  3. La garniture de la tour de refroidissement \u00e0 circuit ferm\u00e9 doit \u00eatre fabriqu\u00e9e en PVC de haute qualit\u00e9 et d\u2019autres mat\u00e9riaux pr\u00e9sentant une forte r\u00e9sistance aux rayons ultraviolets et \u00e0 la corrosion chimique. Le moteur doit pr\u00e9senter un indice d\u2019isolation \u00e9lev\u00e9, de bonnes performances au d\u00e9marrage et un fonctionnement fiable. Quant \u00e0 la tour de refroidissement \u00e0 entra\u00eenement direct non \u00e9quip\u00e9e d\u2019un r\u00e9ducteur, le moteur utilis\u00e9 doit \u00eatre un moteur de s\u00e9rie sup\u00e9rieure, caract\u00e9ris\u00e9 par une vitesse de rotation plus faible et un fonctionnement fluide. Les exigences relatives au ventilateur sont les suivantes : structure raisonnable, faible r\u00e9sistance au vent, grand d\u00e9bit d\u2019air, faible niveau sonore, poids l\u00e9ger et rendement \u00e9lev\u00e9. La capacit\u00e9 de refroidissement est satisfaisante. Les normes de fabrication de certains fabricants de tours de refroidissement ne correspondent pas aux sp\u00e9cifications, et le volume r\u00e9el de la tour de refroidissement est manifestement trop faible, ce qui constitue un exemple typique de r\u00e9duction des co\u00fbts au d\u00e9triment de la qualit\u00e9. Il est \u00e9galement difficile d\u2019obtenir un bon effet de refroidissement, et la vitesse du ventilateur est trop \u00e9lev\u00e9e, ce qui non seulement r\u00e9duira la dur\u00e9e de vie du ventilateur et du moteur, mais provoquera aussi facilement de graves probl\u00e8mes de flottement de l\u2019eau. Lors du choix de la tour de refroidissement, le d\u00e9bit doit \u00eatre \u00e9valu\u00e9 en fonction des besoins r\u00e9els de l\u2019\u00e9quipement. S\u2019il est trop faible, l\u2019effet de refroidissement escompt\u00e9 ne sera pas atteint. S\u2019il est trop \u00e9lev\u00e9, cela entra\u00eenera un gaspillage d\u2019\u00e9nergie inutile. En ce qui concerne les tours de refroidissement carr\u00e9es, dans le cas d\u2019un poids important, compte tenu de la stabilit\u00e9 de fonctionnement et des \u00e9conomies d\u2019\u00e9nergie, il est conseill\u00e9 d\u2019utiliser le type \u00e0 plusieurs ventilateurs en parall\u00e8le. L\u2019implantation globale de la tour de refroidissement doit \u00eatre scientifique et raisonnable. Tout en garantissant la dissipation de la chaleur (refroidissement), la structure doit permettre une bonne circulation de l\u2019air, pr\u00e9senter un bon \u00e9tat de finition, une couleur qui ne se d\u00e9colore pas et \u00eatre facile \u00e0 r\u00e9parer. www.gwbrefrigeration.com<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[13],"tags":[],"acf":[],"_links":{"self":[{"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/posts\/3031"}],"collection":[{"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/comments?post=3031"}],"version-history":[{"count":1,"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/posts\/3031\/revisions"}],"predecessor-version":[{"id":3033,"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/posts\/3031\/revisions\/3033"}],"wp:attachment":[{"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/media?parent=3031"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/categories?post=3031"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/gewabintech.com\/fr\/wp-json\/wp\/v2\/tags?post=3031"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}