Jiangsu gewabin heat technology Co,.Ltd
Introduction
Characteristics of low noise cooling tower
1, Protect media fluid from contamination
2, Maximize system efficiency as highly reduce the fouling and scaling tendencies
3, Energy saving
4, With top brand fan and pump, good technicial design, reduce system maintenance cost,low noise.
Main parts
1. Axial Fan
Three anti - special motor, Protection class is IP55, The Insulation class F, Axial fan with the Aluminum alloy blade. Start directly.
2. Condensing coils
The heat Exchange tube material is high quality SUS 304, 316L tube. grading and pressure test three times to ensure the closeness.
3. Water pump
we use the special cooling tower water pump, the small volume, light weight, silent mode design. easy maintenance and long life
4. Drift eliminator
PVC material drift eliminator change the Airflow direction three times, recycling the steam utmost to save water. It is easy replace.
5. Air inlet louver
PVC material, large air volume, small Wind resistance, can prevent the Floating debris enter the Closed cooling tower.
Application
Low noise square cooling tower widely used for numerous commercial and industrial process cooling applications. Some examples like:
Closed Circuit Cooling Tower Application: | |||
1 | Water-source heat pumps | 5 | Special Fluid Cooling |
2 | Chillers | 6 | Compressor Jacket Cooling |
3 | Data centers | 7 | Machine Jacket Cooling |
4 | Hybrid Evaporative and Dry Cooling | 8 | Induction Furnace |
FAQ
1.Q: Your company is a manufacture or trading company?
A: We are a leading cooling tower manufacturer in China.
2.Q: What if I don't have the professional engineer to install or maintain the product?
A: We could send experience engineers on site to install the product and train your staff for equipment operation and maintenance.
3.Q: How can I choose a suitable model?
A: As long as you provide the following information, we can help select the model for you.
Your Water flow ,Wet-bulb temperature,Inlet and outlet temperature.
EXAMPLE:
Water Flow Rate: (Explanations: How many Tons of water required per hour?)
Inlet Water Temp.: (Explanations: Temperature of hot water to be cooled)
Outlet Water Temp.:
(Explnations: Temperature of cooled water, usually it can't be lower than the wet-bulb temp.)
Wet-bulb Temp.: (Explanations: Highest wet bulb temp. of the location/area or city to install the tower is essential to know to evaluate the size of towers)
Power Supply:
(Explanations: 380V/3 Phases is standard, which we could have in stock,Other can customized
Hot Tags: low noise cooling tower, suppliers, manufacturers, customized, price, HVAC Cooling Tower pric, OEM Wet cooling towers, Industrial small water Cooling Tower, closed circuit Cooling tower philippines, Counter Flow Evaporative Cooling Tower, Water cooling tower system suppliers