{"id":2173,"date":"2026-02-23T13:52:27","date_gmt":"2026-02-23T05:52:27","guid":{"rendered":"http:\/\/192.168.1.196:292\/?p=2173"},"modified":"2026-05-27T13:24:12","modified_gmt":"2026-05-27T05:24:12","slug":"closed-circuit-cooling-water-system","status":"publish","type":"post","link":"https:\/\/gewabintech.com\/pt\/products\/closed-circuit-cooling-tower\/counter-flow-cooling-tower\/closed-circuit-cooling-water-system\/","title":{"rendered":"Sistema de \u00e1gua de arrefecimento de circuito fechado"},"content":{"rendered":"<p><strong>Sistema de \u00e1gua de arrefecimento em circuito fechado Introdu\u00e7\u00e3o<\/strong><\/p>\n<table class=\"table\" border=\"1\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"2\" rowspan=\"1\" height=\"35\">ESPECIFICA\u00c7\u00d5ES PARA A TORRE DE ARREFECIMENTO GWBB-40<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">temperatura de entrada da \u00e1gua<\/td>\n<td height=\"35\">&lt;45\u2103<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">temperatura de sa\u00edda da \u00e1gua<\/td>\n<td height=\"35\">32\u2103<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Temperatura de bulbo h\u00famido<\/td>\n<td height=\"35\">28\u2103<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Circuito interno<\/td>\n<td height=\"35\">40m3\/h<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Press\u00e3o hidr\u00e1ulica<\/td>\n<td style=\"word-break: break-all;\" height=\"35\">0,15-0,35Mpa<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><strong>Detalhes do produto<\/strong><\/p>\n<p>1. Ventilador axial<\/p>\n<p>Tr\u00eas motores anti-especiais, a classe de prote\u00e7\u00e3o \u00e9 IP55, a classe de isolamento F, ventilador axial com l\u00e2mina de liga de alum\u00ednio. Arranque direto.<\/p>\n<p>2. Serpentinas de condensa\u00e7\u00e3o<\/p>\n<p>O material do tubo de troca de calor \u00e9 um tubo de cobre de alta qualidade ou o tubo SUS 304, 316L. classifica\u00e7\u00e3o e teste de press\u00e3o tr\u00eas vezes para garantir a proximidade.<\/p>\n<p>3. Bomba de \u00e1gua<\/p>\n<p>usamos a bomba de \u00e1gua especial para torre de resfriamento, motor WEG, o pequeno volume, peso leve, design de modo silencioso. f\u00e1cil manuten\u00e7\u00e3o e longa vida \u00fatil.<\/p>\n<p>4. Eliminador de derivas<\/p>\n<p>O eliminador de deriva de material PVC muda a dire\u00e7\u00e3o do fluxo de ar tr\u00eas vezes, reciclando o vapor ao m\u00e1ximo para poupar \u00e1gua. \u00c9 f\u00e1cil de substituir.<\/p>\n<p>5. Grelha de entrada de ar<\/p>\n<p>Material de PVC, grande volume de ar, pequena resist\u00eancia ao vento, pode impedir que os detritos flutuantes entrem na torre de arrefecimento fechada.<\/p>\n<p>6. Sistema de pulveriza\u00e7\u00e3o de \u00e1gua<\/p>\n<p>O bocal de pulveriza\u00e7\u00e3o \u00e9 o mais importante, pois pode garantir que a \u00e1gua pulverizada no tubo de permuta de calor seja uniforme.<\/p>\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" width=\"700\" height=\"800\" class=\"wp-image-3161\" src=\"\/wp-content\/uploads\/2023\/12\/968086589bd39e43dbe1.jpg\"  srcset=\"https:\/\/gewabintech.com\/wp-content\/uploads\/2023\/12\/968086589bd39e43dbe1.jpg 700w, https:\/\/gewabintech.com\/wp-content\/uploads\/2023\/12\/968086589bd39e43dbe1-525x600.jpg 525w\" sizes=\"(max-width: 700px) 100vw, 700px\" title=\"Sistema de \u00e1gua de arrefecimento de circuito fechado \u63d2\u56fe\" alt=\"Closed Circuit Cooling Water System\u63d2\u56fe\" \/><\/figure>\n<p>&nbsp;<\/p>\n<p><strong>PROCESSO DE PRODU\u00c7\u00c3O<\/strong><\/p>\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" width=\"700\" height=\"204\" class=\"wp-image-3162\" src=\"\/wp-content\/uploads\/2023\/12\/47feb0b1296d5515f95d.jpg\"  srcset=\"https:\/\/gewabintech.com\/wp-content\/uploads\/2023\/12\/47feb0b1296d5515f95d.jpg 700w, https:\/\/gewabintech.com\/wp-content\/uploads\/2023\/12\/47feb0b1296d5515f95d-600x175.jpg 600w\" sizes=\"(max-width: 700px) 100vw, 700px\" title=\"Sistema de \u00e1gua de arrefecimento de circuito fechado \u63d2\u56fe1\" alt=\"Closed Circuit Cooling Water System\u63d2\u56fe1\" \/><\/figure>\n<p>&nbsp;<\/p>\n<p><strong>Guia de sele\u00e7\u00e3o<\/strong><\/p>\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" width=\"416\" height=\"128\" class=\"wp-image-3165\" src=\"\/wp-content\/uploads\/2023\/12\/56f2d9f573f8292a8ffe.jpg\" title=\"Sistema de \u00e1gua de arrefecimento de circuito fechado \u63d2\u56fe2\" alt=\"Closed Circuit Cooling Water System\u63d2\u56fe2\" \/><\/figure>\n<\/div>\n<p>&nbsp;<\/p>\n<p>1. o caudal de \u00e1gua de arrefecimento G=m3\/h<\/p>\n<p>2.otemperatura da torre de colagem de entrada T1=\u2103<\/p>\n<p>3. a temperatura da torre de arrefecimento de sa\u00edda T2=\u2103<\/p>\n<p>4.o c\u00e1lculo da temperatura de bolbo h\u00famido do local de instala\u00e7\u00e3o T=\u2103<\/p>\n<p>O c\u00e1lculo da rejei\u00e7\u00e3o de calor da torre de arrefecimento fechada<\/p>\n<p>Q=1,163xGx(T1-T2)<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Vantagens do sistema de \u00e1gua de arrefecimento em circuito fechado<\/strong><\/p>\n<p>1. Estabilidade: A circula\u00e7\u00e3o <a href=\"https:\/\/www.dereforma.com\/\"><strong>Diyarbak\u0131r Acompanhante<\/strong><\/a> a \u00e1gua da torre de arrefecimento fechada adopta normalmente um circuito fechado de \u00e1gua macia <a href=\"https:\/\/www.dereforma.com\/\"><strong>Diyarbak\u0131r Acompanhante Bayan<\/strong><\/a> circula\u00e7\u00e3o, o que evita eficazmente os danos ao <a href=\"https:\/\/www.dereforma.com\/\"><strong>Acompanhante Diyarbak\u0131r <\/strong><\/a>equipamento causado pela escala gerada na torre ou no equipamento do utilizador durante a utiliza\u00e7\u00e3o a longo prazo.<\/p>\n<p>2. Poupan\u00e7a de \u00e1gua: Em compara\u00e7\u00e3o com as torres de arrefecimento tradicionais, as torres de arrefecimento fechadas s\u00e3o mais adequadas para utiliza\u00e7\u00e3o em \u00e1reas onde os recursos h\u00eddricos s\u00e3o escassos devido \u00e0 utiliza\u00e7\u00e3o de circula\u00e7\u00e3o interna totalmente fechada e \u00e0 utiliza\u00e7\u00e3o de dispositivos de desidrata\u00e7\u00e3o de elevada efici\u00eancia.<\/p>\n<p>3. Poupan\u00e7a de energia: a torre de arrefecimento fechada pode controlar o n\u00famero de ventiladores a arrancar de acordo com a temperatura, e a bomba de pulveriza\u00e7\u00e3o \u00e9 ligada e desligada, podendo tamb\u00e9m ser instalada uma v\u00e1lvula reguladora para controlar o caudal.<\/p>\n<p>4. Prote\u00e7\u00e3o do ambiente: A torre de resfriamento fechada n\u00e3o ser\u00e1 polu\u00edda pela \u00e1gua circulante do circuito interno totalmente fechado e pode ser usada continuamente. A evapora\u00e7\u00e3o relativa da \u00e1gua pulverizada \u00e9 pequena, o que protege o ambiente.<\/p>\n<p>5. Vida \u00fatil mais longa: A nossa empresa utiliza materiais met\u00e1licos de alta qualidade, o que melhora muito a sua capacidade de utiliza\u00e7\u00e3o. O per\u00edodo de servi\u00e7o \u00e9 geralmente superior a 10, e a manuten\u00e7\u00e3o posterior e o custo s\u00e3o mais baixos.<\/p>\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" width=\"700\" height=\"522\" class=\"wp-image-3163\" src=\"\/wp-content\/uploads\/2023\/12\/d5e3dc6d41eb1796fdb7.jpg\"  srcset=\"https:\/\/gewabintech.com\/wp-content\/uploads\/2023\/12\/d5e3dc6d41eb1796fdb7.jpg 700w, https:\/\/gewabintech.com\/wp-content\/uploads\/2023\/12\/d5e3dc6d41eb1796fdb7-600x447.jpg 600w\" sizes=\"(max-width: 700px) 100vw, 700px\" title=\"Sistema de \u00e1gua de arrefecimento de circuito fechado \u63d2\u56fe3\" alt=\"Closed Circuit Cooling Water System\u63d2\u56fe3\" \/><\/figure>\n<p>&nbsp;<\/p>\n<p>Jiangsu Gewabin Thermal Energy Technology Co., Ltd. \u00e9 um fabricante especializado na ind\u00fastria de refrigera\u00e7\u00e3o. A empresa tem equipamento de produ\u00e7\u00e3o perfeito e for\u00e7a t\u00e9cnica forte.<\/p>\n<p>Tamb\u00e9m podemos personalizar produtos de acordo com os requisitos do cliente e fornecer servi\u00e7os de processamento e produtos OEM.<\/p>\n<p>Ouvimos sempre ativamente as suas opini\u00f5es para lhe oferecermos o design perfeito para satisfazer as suas necessidades.<\/p>\n<p>&nbsp;<\/p>\n<p>Hot Tags: sistema de \u00e1gua de resfriamento de circuito fechado, fornecedores, fabricantes, personalizado, pre\u00e7o, OEM HVAC Torre de resfriamento, sistema de resfriamento de circuito fechado, circuito fechado Torre de resfriamento Filipinas, China Torres de resfriamento e refrigeradores de fluido adiab\u00e1tico, Torres de resfriamento e f\u00e1brica de refrigeradores de fluido adiab\u00e1tico, fornecedores de refrigeradores de fluido adiab\u00e1tico<\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>Closed circuit cooling water system\u00a0Introduction SPECIFICATIONS FOR GWBB-40 COOLING TOWER water inlet temperature &lt;45\u2103 water outlet temperature 32\u2103 Wet-bulb temperature 28\u2103 Inner loop 40m3\/h Hydraulic pressure 0.15-0.35Mpa &nbsp; Product details 1. Axial Fan Three anti &#8211; special motor, \u00a0Protection class is IP55, The Insulation class F, Axial fan with the Aluminum alloy blade. Start directly. 2. Condensing coils The heat Exchange tube material is high quality copper tube or the SUS 304, 316L tube. grading and pressure test three times to ensure the closeness. 3. Water pump we use the special cooling tower water pump,WEG motor, \u00a0the small volume, light weight, silent mode design. easy maintenance and long life. 4. Drift eliminator PVC material drift eliminator change the Airflow direction three times, recycling the steam utmost to save water. It is easy replace. 5. Air inlet louver PVC material, large air volume, small Wind resistance, can prevent the Floating debris enter the Closed cooling tower. 6. Water Spray system The spray nozzle is most important, it can ensure the water sprayed on heat exchanged tube evenly. &nbsp; PRODUCTION PROCESS &nbsp; Selection Guide &nbsp; 1.The cooling water flow \u00a0G=m3\/h 2.Thetempeatue of inlet coling tower T1=\u2103 3.The tempeatue of outlet coling tower T2=\u2103 4.The calculation wet bulb temperature of installation location T=\u2103 The heat rejction calculation od closed cooling tower Q=1.163xGx(T1-T2) &nbsp; Advantage\u00a0of closed circuit cooling water system 1. Stability: The circulating Diyarbak\u0131r Escort water of the closed cooling tower usually adopts soft water closed circuit Diyarbak\u0131r Escort Bayan circulation, which effectively prevents the damage to the Escort Diyarbak\u0131r equipment caused by the scale generated in the tower or the user equipment during the long-term use. 2. Water saving: Compared with traditional cooling towers, closed cooling towers are more suitable for use in areas where water resources are scarce because of the use of fully enclosed internal circulation and the use of high-efficiency dehydration devices. 3. Energy saving: the closed cooling tower can control the number of fans to start according to the temperature, and the spray pump is turned on and off, and a regulating valve can also be installed to control the flow rate. 4. Environmental protection: The closed cooling tower will not be polluted by the fully enclosed internal circuit circulating water and can be used continuously. The relative evaporation of spray water is small, which protects the environment. 5. Longer service life: Our company uses high-quality metal materials, which greatly improves its ability to use. The service period is usually more than 10, and the later maintenance and cost are lower. &nbsp; Jiangsu Gewabin Thermal Energy Technology Co., Ltd. is a manufacturer specializing in the refrigeration industry. The company has perfect production equipment and strong technical force. We can also customize products according to customer requirements, and provide processing services and OEM products. We always actively listen to your opinions to provide the perfect design to meet your needs. &nbsp; Hot Tags: closed circuit cooling water system, suppliers, manufacturers, customized, price, OEM HVAC Cooling Tower, closed circuit cooling [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":2147,"comment_status":"open","ping_status":"open","sticky":true,"template":"","format":"standard","meta":[],"categories":[46],"tags":[],"acf":[],"_links":{"self":[{"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/posts\/2173"}],"collection":[{"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/comments?post=2173"}],"version-history":[{"count":3,"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/posts\/2173\/revisions"}],"predecessor-version":[{"id":5816,"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/posts\/2173\/revisions\/5816"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/media\/2147"}],"wp:attachment":[{"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/media?parent=2173"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/categories?post=2173"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/tags?post=2173"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}