{"id":2175,"date":"2023-12-14T13:53:53","date_gmt":"2023-12-14T05:53:53","guid":{"rendered":"http:\/\/192.168.1.196:292\/?p=2175"},"modified":"2024-08-05T16:17:12","modified_gmt":"2024-08-05T08:17:12","slug":"closed-circuit-industrial-cooling-tower","status":"publish","type":"post","link":"https:\/\/gewabintech.com\/pt\/products\/closed-circuit-cooling-tower\/counter-flow-cooling-tower\/closed-circuit-industrial-cooling-tower\/","title":{"rendered":"Torre de arrefecimento industrial de circuito fechado"},"content":{"rendered":"<p><strong>Estrutura e princ\u00edpio de funcionamento<\/strong><\/p>\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" width=\"541\" height=\"389\" src=\"\/wp-content\/uploads\/2023\/12\/4ca1c48265401af2bc9e.jpg\"  class=\"wp-image-3138\" title=\"Ilustra\u00e7\u00e3o de uma torre de refrigera\u00e7\u00e3o industrial de circuito fechado\" alt=\"Closed Circuit Industrial Cooling Tower\u63d2\u56fe\" \/><\/figure>\n<p>Durante o funcionamento, o fluido de arrefecimento \u00e9 impulsionado por uma bomba de circula\u00e7\u00e3o principal, que faz circular o fluxo entre o permutador de calor e o equipamento. A \u00e1gua \u00e9 pulverizada sobre o permutador de calor para formar uniformemente uma pel\u00edcula de \u00e1gua na superf\u00edcie de permuta de calor. O ar frio entra na torre pela entrada de ar situada na parte inferior, passando pela superf\u00edcie do permutador de calor. Existem dois m\u00e9todos de permuta de calor neste processo. A transfer\u00eancia de calor entre o ar frio e o meio de arrefecimento, bem como a troca de calor do vapor e a absor\u00e7\u00e3o de calor pela \u00e1gua pulverizada. O ar quente \u00e9 expelido do sistema para a atmosfera. A restante \u00e1gua flui para o reservat\u00f3rio situado por baixo da torre. Em seguida, \u00e9 bombeada para o sistema de aspers\u00e3o. O meio de arrefecimento no permutador de calor de movimento rec\u00edproco \u00e9 arrefecido.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Vantagens<\/strong><\/p>\n<p>1. Adotar o processo de soldadura por arco de arg\u00e3o com inversor e submeter a pe\u00e7a a v\u00e1rios ensaios de press\u00e3o a 2,75 MPa, a fim de garantir a qualidade da soldadura e a resist\u00eancia geral \u00e0 press\u00e3o.<\/p>\n<p>2. A chapa de a\u00e7o galvanizado da carca\u00e7a apresenta boa resist\u00eancia \u00e0 humidade, \u00e0 oxida\u00e7\u00e3o e \u00e0 corros\u00e3o.<\/p>\n<p>3. S\u00e3o utilizados um motor especial para a torre de arrefecimento, uma ventoinha e uma tecnologia exclusiva de aspers\u00e3o e elimina\u00e7\u00e3o<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Instru\u00e7\u00f5es de utiliza\u00e7\u00e3o<\/strong><\/p>\n<p>1. Antes de escolher o produto, pode indicar-nos a temperatura da \u00e1gua \u00e0 entrada, a temperatura da \u00e1gua \u00e0 sa\u00edda e a temperatura do bulbo h\u00famido do ar.<\/p>\n<p>2. Os nossos produtos podem funcionar a -50 \u00b0C; se a temperatura m\u00e9dia mais baixa for inferior a -10 \u00b0C, deve informar-nos disso no momento da encomenda, para que possamos tomar medidas contra o gelo.<\/p>\n<p>3. A turbidez da \u00e1gua em circula\u00e7\u00e3o \u00e9 inferior a 50 mg\/L, estando isenta de \u00f3leo e impurezas.<\/p>\n<p>4. A temperatura da \u00e1gua \u00e0 entrada \u00e9 inferior a 60 \u00b0C.<\/p>\n<p>5. Os tubos de entrada e sa\u00edda podem ser rodados 90\u00b0, 180\u00b0 e 270\u00b0.<\/p>\n<p>6. O \u00e2ngulo das p\u00e1s do ventilador \u00e9 ajust\u00e1vel, para garantir que todas fiquem no mesmo \u00e2ngulo.<\/p>\n<p>7. N\u00e3o exceda a corrente nominal do motor.<\/p>\n<p>8. Tenha cuidado com o fogo e a press\u00e3o.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Os nossos servi\u00e7os<\/strong><\/p>\n<p>Servi\u00e7os pr\u00e9-venda:&nbsp; &nbsp;<\/p>\n<p>(1) Explicar aos clientes como utilizar os nossos produtos<\/p>\n<p>(2) Orientar os clientes na escolha do produto mais adequado e econ\u00f3mico, de modo a recuperar o investimento num curto espa\u00e7o de tempo.  Servi\u00e7os p\u00f3s-venda:&nbsp;&nbsp;<\/p>\n<p>O controlo de qualidade deve ser rigorosamente verificado. &nbsp;<\/p>\n<p>Servi\u00e7os p\u00f3s-venda:&nbsp; &nbsp;<\/p>\n<p>Normalmente, a garantia dos nossos produtos \u00e9 de 18 meses a contar da sa\u00edda da f\u00e1brica ou de 12 meses a contar da instala\u00e7\u00e3o. Durante esse per\u00edodo, a nossa f\u00e1brica assume a responsabilidade por todas as pe\u00e7as que se avariem.<\/p>\n<p>(3) Contacto regular com os clientes. Atualizar os nossos produtos com base no feedback dos clientes.<\/p>\n<p>&nbsp;<\/p>\n<p>Palavras-chave: torre de arrefecimento industrial de circuito fechado, fornecedores, fabricantes, personalizada, pre\u00e7o, fabricantes de torres de arrefecimento HVAC, fabricantes de torres de arrefecimento e refrigeradores adiab\u00e1ticos de fluidos, torre de arrefecimento industrial de circuito fechado, f\u00e1brica de torres de arrefecimento e refrigeradores adiab\u00e1ticos de fluidos, pre\u00e7o da torre de arrefecimento a \u00e1gua, refrigeradores adiab\u00e1ticos de fluidos<\/p>","protected":false},"excerpt":{"rendered":"<p>Structure and working principle During operation, the cooling medium is driven by a main circulating pump circulating flow between the heat exchanger and the equipment. The water is sprayed on the heat exchanger to uniformly form a water film on the heat exchange surface. Cold air enters the tower from the underlying air inlet through the surface of the heat exchanger surface. There are two methods of heat exchange in this process. Heat transfer between the cold air and the cooling medium, as well as the heat exchange of the steam and the heat absorption of the water spray. Hot air is vented from the air to the atmosphere. Other water flows into the sink below the tower. Then pump them into the sprinkler system. The cooling medium in the reciprocating heat exchanger is cooled. &nbsp; Advantages 1. Adopt the inverter argon arc welding process and pass the 2.75mpa pressure test for many times to ensure the welding quality and overall pressure resistance. 2. The alloy galvanized steel sheet of the shell has good moisture resistance, oxidation resistance and corrosion resistance. 3. Cooling tower special motor, fan and unique drenching and elimination technology are adopted &nbsp; Using instruction 1. Before you choose the product, you can provide us with the inlet water temperature, the outlet water temperature, and the air wet bulb temperature. 2. Our products can run at -50 \u00b0 C, the coldest average temperature is below -10 \u00b0 C, you should tell us when ordering, we will take anti-ice measures. 3. Circulating water turbidity is less than 50 mg \/ L, free of oil and impurities. 4. The inlet water temperature is below 60 \u00b0C. 5. The inlet and outlet pipes can be rotated by 90\u00b0, 180\u00b0 and 270\u00b0. 6. The fan blade angle is adjustable to ensure the same angle. 7. Do not exceed the rated current of the motor. 8. Pay attention to fire and pressure. &nbsp; Our Services Before-sale services:&nbsp; &nbsp; (1) Tell customers how to use our products (2) Guide customers to choose the best and economic product, recover the investment within short time.&nbsp; In-Sale services:&nbsp;&nbsp; Quality control must be inspected strictly. &nbsp; After-sale services:&nbsp; &nbsp; Usually, our product warranty is 18 months after leaving factory or 12 months after installation. within this months, all parts broken will be responsible for our factory. (3) Regular contact with customers. Update our products based on the feedback of customers. &nbsp; Hot Tags: closed circuit industrial cooling tower, suppliers, manufacturers, customized, price, HVAC Cooling Tower manufacturers, Cooling Towers And Adiabatic Fluid Coolers manufacturers, Closed circuit industrial cooling tower, Cooling Towers And Adiabatic Fluid Coolers factory, Water Cooling Tower pric, Adiabatic Fluid Coolers<\/p>","protected":false},"author":1,"featured_media":2148,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[46],"tags":[],"acf":[],"_links":{"self":[{"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/posts\/2175"}],"collection":[{"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/comments?post=2175"}],"version-history":[{"count":5,"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/posts\/2175\/revisions"}],"predecessor-version":[{"id":3893,"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/posts\/2175\/revisions\/3893"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/media\/2148"}],"wp:attachment":[{"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/media?parent=2175"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/categories?post=2175"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/tags?post=2175"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}