{"id":2330,"date":"2023-12-18T09:36:24","date_gmt":"2023-12-18T01:36:24","guid":{"rendered":"http:\/\/gewabin.wangluocloud.com\/?p=2330"},"modified":"2024-08-06T09:34:48","modified_gmt":"2024-08-06T01:34:48","slug":"cooling-towers-and-evaporative-condensers-2","status":"publish","type":"post","link":"https:\/\/gewabintech.com\/pt\/products\/closed-circuit-cooling-tower\/cross-flow-cooling-tower\/cooling-towers-and-evaporative-condensers-2\/","title":{"rendered":"Torres de arrefecimento e condensadores evaporativos"},"content":{"rendered":"<p><strong>Introdu\u00e7\u00e3o<\/strong><\/p>\n<p>Cooling Towers and Evaporative Condensers can be used in air conditioners, instrumentation, metallurgical intermediate frequency electric furnaces, converters, power plant generator sets, steam turbine nuclear power plants, substations, chemical, pharmaceutical, welding, aluminum, copper foil cooling oil, large hydraulic machinery hydraulic oil Used in industrial manufacturing fields.<\/p>\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" width=\"750\" height=\"647\" src=\"\/wp-content\/uploads\/2024\/01\/4b4561b344359d9ee4b1.jpg\"  class=\"wp-image-2830\" srcset=\"https:\/\/gewabintech.com\/wp-content\/uploads\/2024\/01\/4b4561b344359d9ee4b1.jpg 750w, https:\/\/gewabintech.com\/wp-content\/uploads\/2024\/01\/4b4561b344359d9ee4b1-600x518.jpg 600w\" sizes=\"(max-width: 750px) 100vw, 750px\" title=\"Cooling Towers And Evaporative Condensers\u63d2\u56fe\" alt=\"Cooling Towers And Evaporative Condensers\u63d2\u56fe\" \/><\/figure>\n<p>&nbsp;<\/p>\n<p><strong>Technical Parameter<\/strong><\/p>\n<figure class=\"wp-block-table table\">\n<table width=\"100%\" border=\"1\">\n<tbody>\n<tr>\n<td height=\"35\">Componentes principais<\/td>\n<td height=\"35\">&nbsp;<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Condenser&nbsp;Coil<\/td>\n<td height=\"35\">Fabricado com tubos de a\u00e7o sem costura de alta qualidade. A unidade de bobina \u00e9 feita de a\u00e7o inoxid\u00e1vel SS-304\/316L. A press\u00e3o m\u00e1xima das nossas bobinas pode chegar a 32Mpa.<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Bomba de pulveriza\u00e7\u00e3o<\/td>\n<td height=\"35\">Vedado por um vedante de maquinaria rotativo sem limites de qualidade superior, sem fugas, ciclo de vida longo, pot\u00eancia reduzida, grande volume de fluxo, baixo ru\u00eddo e elevado desempenho.<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Ventilador<\/td>\n<td height=\"35\">Tipo axial; h\u00e9lice em liga de alum\u00ednio<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Inv\u00f3lucro<\/td>\n<td height=\"35\">Chapa de liga de alum\u00ednio-zinco SS-304\/316L ou importada, chapa de Mg-Al-zinco<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Dispositivo el\u00e9trico de tratamento de \u00e1gua<\/td>\n<td height=\"35\">Limpar a \u00e1gua do circuito, evitar eficazmente a forma\u00e7\u00e3o de incrusta\u00e7\u00f5es na superf\u00edcie das bobinas e dos enchimentos de PVC.<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Eliminador de deriva amov\u00edvel<\/td>\n<td height=\"35\">Material de PVC; certificar-se de que a taxa de perda de \u00e1gua \u00e9 inferior a 0,002%<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Enchimento da torre de arrefecimento<\/td>\n<td height=\"35\">100% Material original PVC Infill, design especial com grande efeito de arrefecimento<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p>&nbsp;<\/p>\n<p><strong>Princ\u00edpio de funcionamento<\/strong><\/p>\n<p>A \u00e1gua da bacia \u00e9 bombeada para o tubo coletor, passa pelos bicos de distribui\u00e7\u00e3o e \u00e9 pulverizada sobre os tubos da serpentina de troca de calor. Forma-se uma camada uniforme de \u00e1gua \u00e0 volta da superf\u00edcie exterior dos tubos; o ar frio entra no corpo da torre atrav\u00e9s da entrada de ar lateral e flui atrav\u00e9s da camada de \u00e1gua no exterior dos tubos da serpentina em dire\u00e7\u00f5es opostas \u00e0 da \u00e1gua pulverizada; uma parte da \u00e1gua pulverizada evapora-se e absorve calor da \u00e1gua presente na serpentina. O ar absorve esse calor, bem como o calor transferido por contacto, e transforma-se em ar quente e h\u00famido saturado, sendo depois descarregado para a atmosfera atrav\u00e9s do exaustor superior; a \u00e1gua pulverizada restante flui para o tubo coletor na parte inferior da torre e \u00e9 bombeada de volta para o ciclo de pulveriza\u00e7\u00e3o.<\/p>\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" width=\"341\" height=\"245\" src=\"\/wp-content\/uploads\/2024\/01\/c073de86e7dfd38e8672.jpg\"  class=\"wp-image-3323\" title=\"Cooling Towers And Evaporative Condensers\u63d2\u56fe1\" alt=\"Cooling Towers And Evaporative Condensers\u63d2\u56fe1\" \/><\/figure>\n<\/div>\n<p>&nbsp;<\/p>\n<p><strong>Guia de sele\u00e7\u00e3o<\/strong><\/p>\n<p>1.The cooling water flow&nbsp; G=m3\/h<\/p>\n<p>2.The temperature of inlet cooling tower T1=\u2103<\/p>\n<p>3. A temperatura de sa\u00edda da torre de arrefecimento T2 = \u2103<\/p>\n<p>4.o c\u00e1lculo da temperatura de bolbo h\u00famido do local de instala\u00e7\u00e3o T=\u2103<\/p>\n<p>The heat rejection calculation of closed cooling tower<\/p>\n<p>Q=1,163xGx(T1-T2)<\/p>\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" width=\"416\" height=\"128\" src=\"\/wp-content\/uploads\/2023\/12\/56f2d9f573f8292a8ffe.jpg\"  class=\"wp-image-3165\" title=\"Cooling Towers And Evaporative Condensers\u63d2\u56fe2\" alt=\"Cooling Towers And Evaporative Condensers\u63d2\u56fe2\" \/><\/figure>\n<\/div>\n<p>&nbsp;<\/p>\n<p><strong>Aplica\u00e7\u00e3o<\/strong><\/p>\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" width=\"410\" height=\"900\" src=\"\/wp-content\/uploads\/2023\/12\/7aa4fb84139ea32e21a5-410x900.jpg\"  class=\"wp-image-3352\" srcset=\"https:\/\/gewabintech.com\/wp-content\/uploads\/2023\/12\/7aa4fb84139ea32e21a5-410x900.jpg 410w, https:\/\/gewabintech.com\/wp-content\/uploads\/2023\/12\/7aa4fb84139ea32e21a5-274x600.jpg 274w, https:\/\/gewabintech.com\/wp-content\/uploads\/2023\/12\/7aa4fb84139ea32e21a5-700x1536.jpg 700w, https:\/\/gewabintech.com\/wp-content\/uploads\/2023\/12\/7aa4fb84139ea32e21a5.jpg 750w\" sizes=\"(max-width: 410px) 100vw, 410px\" title=\"Cooling Towers And Evaporative Condensers\u63d2\u56fe3\" alt=\"Cooling Towers And Evaporative Condensers\u63d2\u56fe3\" \/><\/figure>\n<p>&nbsp;<\/p>\n<p>Hot Tags: cooling towers and evaporative condensers, suppliers, manufacturers, customized, price, Water Cooling Evaporative Fluid Cooler, evaporative condenser chiller, Industrial Cooling Tower factory, cross flow type cooling tower, Anti noise Square Cooling Tower, fluid cooler cooling tower<\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>Introduction Cooling Towers and Evaporative Condensers can be used in air conditioners, instrumentation, metallurgical intermediate frequency electric furnaces, converters, power plant generator sets, steam turbine nuclear power plants, substations, chemical, pharmaceutical, welding, aluminum, copper foil cooling oil, large hydraulic machinery hydraulic oil Used in industrial manufacturing fields. &nbsp; Technical Parameter Main Components &nbsp; Condenser&nbsp;Coil Made of high-quality seamless steel pipes. The coil unit are &nbsp;made by SS-304\/316L stainless steel. Maximum pressure of our coils could reach to 32Mpa. Spray Pump Sealed by top quality rotary no-limited machinery seal, no leaking, long lifecycle, small horse power, large flow volume, low noise and high performance. Fan Axial type;aluminum alloy propeller Casing SS-304\/316L or imported Aluminum-zinc alloy plate,&nbsp;Mg-Al-zinc plate Electric Water Treatment Device Clear the circuit water, effectively avoid the scale forming on the surface of coils and PVC fills. Removable Drift Eliminator PVC material; Make sure that the water loss rate will be less than 0.002% Cooling Tower Fill 100% Original Material PVC Infill, special design with great cooling effect &nbsp; Working Principle The water in the basin is pumped to the collector pipe, goes through distribution nozzles and sprays to heat-exchange coil pipes. An even water layer is formed around the outer surface of the pipes, cold air enters to the tower body through the air inlet of the tower lateral and flow through water layer outside the coil pipes in opposite directions from the spray water; a part of the spray water evaporates and absorbs heat from the water in coil. The air absorbs the said heat as well as heat transfer by contact, and becomes saturated hot humid air, then discharges to the atmosphere from the top exhaust fan, the rest spray water flows to the collector pipe at low part of tower and is pumped to spraying cycle. &nbsp; Selection Guide 1.The cooling water flow&nbsp; G=m3\/h 2.The temperature of inlet cooling tower T1=\u2103 3.The temperature of outlet cooling tower T2=\u2103 4.The calculation wet bulb temperature of installation location T=\u2103 The heat rejection calculation of closed cooling tower Q=1.163xGx(T1-T2) &nbsp; Application &nbsp; Hot Tags: cooling towers and evaporative condensers, suppliers, manufacturers, customized, price, Water Cooling Evaporative Fluid Cooler, evaporative condenser chiller, Industrial Cooling Tower factory, cross flow type cooling tower, Anti noise Square Cooling Tower, fluid cooler cooling tower &nbsp;<\/p>","protected":false},"author":1,"featured_media":2331,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[47],"tags":[],"acf":[],"_links":{"self":[{"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/posts\/2330"}],"collection":[{"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/comments?post=2330"}],"version-history":[{"count":5,"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/posts\/2330\/revisions"}],"predecessor-version":[{"id":3933,"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/posts\/2330\/revisions\/3933"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/media\/2331"}],"wp:attachment":[{"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/media?parent=2330"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/categories?post=2330"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/tags?post=2330"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}