{"id":2344,"date":"2023-12-18T09:38:50","date_gmt":"2023-12-18T01:38:50","guid":{"rendered":"http:\/\/gewabin.wangluocloud.com\/?p=2344"},"modified":"2024-08-06T09:32:02","modified_gmt":"2024-08-06T01:32:02","slug":"cross-circuit-cooling-tower","status":"publish","type":"post","link":"https:\/\/gewabintech.com\/pt\/products\/closed-circuit-cooling-tower\/cross-flow-cooling-tower\/cross-circuit-cooling-tower\/","title":{"rendered":"Torre de arrefecimento de circuito cruzado"},"content":{"rendered":"<p><strong>Princ\u00edpio de funcionamento:<\/strong><\/p>\n<p>1. Circula\u00e7\u00e3o interna: A \u00e1gua em circula\u00e7\u00e3o entra no radiador de superf\u00edcie ap\u00f3s a troca de calor com a fonte de calor; o calor \u00e9 dissipado para o exterior atrav\u00e9s do radiador de superf\u00edcie e a \u00e1gua em circula\u00e7\u00e3o arrefecida \u00e9 enviada para a fonte de calor pela bomba de \u00e1gua.<\/p>\n<p>2. Circula\u00e7\u00e3o externa: A \u00e1gua de pulveriza\u00e7\u00e3o \u00e9 enviada do dep\u00f3sito de \u00e1gua para o sistema de pulveriza\u00e7\u00e3o. Depois de pulverizada, a \u00e1gua entra em contacto com o refrigerador de superf\u00edcie para a troca de calor. Parte do vapor quente \u00e9 descarregada atrav\u00e9s do ventilador. A \u00e1gua de pulveriza\u00e7\u00e3o arrefecida cai no dep\u00f3sito de \u00e1gua e volta a circular.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Detalhes do produto<\/strong><\/p>\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" width=\"760\" height=\"474\" src=\"\/wp-content\/uploads\/2023\/12\/b23e0cdfa1edfd0377e6.jpg\"  class=\"wp-image-3345\" srcset=\"https:\/\/gewabintech.com\/wp-content\/uploads\/2023\/12\/b23e0cdfa1edfd0377e6.jpg 760w, https:\/\/gewabintech.com\/wp-content\/uploads\/2023\/12\/b23e0cdfa1edfd0377e6-600x374.jpg 600w\" sizes=\"(max-width: 760px) 100vw, 760px\" title=\"Ilustra\u00e7\u00e3o de uma torre de refrigera\u00e7\u00e3o de circuito cruzado\" alt=\"Cross Circuit Cooling Tower\u63d2\u56fe\" \/><\/figure>\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" width=\"757\" height=\"469\" src=\"\/wp-content\/uploads\/2023\/12\/b728fe12eac4c0a608cc.jpg\"  class=\"wp-image-3346\" srcset=\"https:\/\/gewabintech.com\/wp-content\/uploads\/2023\/12\/b728fe12eac4c0a608cc.jpg 757w, https:\/\/gewabintech.com\/wp-content\/uploads\/2023\/12\/b728fe12eac4c0a608cc-600x372.jpg 600w\" sizes=\"(max-width: 757px) 100vw, 757px\" title=\"Torre de arrefecimento de circuito cruzado \u2014 Ilustra\u00e7\u00e3o 1\" alt=\"Cross Circuit Cooling Tower\u63d2\u56fe1\" \/><\/figure>\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" width=\"757\" height=\"226\" src=\"\/wp-content\/uploads\/2023\/12\/75c68d6a718856cdea05.jpg\"  class=\"wp-image-3347\" srcset=\"https:\/\/gewabintech.com\/wp-content\/uploads\/2023\/12\/75c68d6a718856cdea05.jpg 757w, https:\/\/gewabintech.com\/wp-content\/uploads\/2023\/12\/75c68d6a718856cdea05-600x179.jpg 600w\" sizes=\"(max-width: 757px) 100vw, 757px\" title=\"Torre de arrefecimento de circuito cruzado \u2014 Ilustra\u00e7\u00e3o 2\" alt=\"Cross Circuit Cooling Tower\u63d2\u56fe2\" \/><\/figure>\n<p>&nbsp;<\/p>\n<p><strong>Manuten\u00e7\u00e3o e conserva\u00e7\u00e3o da torre de arrefecimento fechada<\/strong><\/p>\n<p>a. No caso da torre de arrefecimento fechada, mantenha limpa a superf\u00edcie da bobina de dissipa\u00e7\u00e3o de calor (arrefecedor), garanta a circula\u00e7\u00e3o de ar \u00e0 sua volta, limpe regularmente o p\u00f3, as manchas de \u00f3leo e outros res\u00edduos presentes no permutador de calor, para evitar que o volume de ar e a efic\u00e1cia da dissipa\u00e7\u00e3o de calor sejam afetados, e limpe regularmente o filtro de pulveriza\u00e7\u00e3o.<\/p>\n<p>b. Se a torre de arrefecimento fechada ficar desativada durante algum tempo, a bomba pode ficar bloqueada devido \u00e0 acumula\u00e7\u00e3o de res\u00edduos da \u00e1gua. Quando a m\u00e1quina for ligada, \u00e9 necess\u00e1rio soltar o rotor da bomba para evitar que as p\u00e1s da bomba n\u00e3o girem, o que resultaria na queima do fus\u00edvel.<\/p>\n<p>c. Ap\u00f3s a torre de arrefecimento fechada ter sido utilizada num ambiente empoeirado durante algum tempo, a parede exterior do tubo pode ficar incrustada. A forma\u00e7\u00e3o de incrusta\u00e7\u00f5es reduzir\u00e1 a capacidade de arrefecimento do equipamento. Recomenda-se a remo\u00e7\u00e3o dessas incrusta\u00e7\u00f5es.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Aplica\u00e7\u00e3o<\/strong><\/p>\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" width=\"700\" height=\"700\" src=\"\/wp-content\/uploads\/2023\/12\/db15aa2b4b46b15c5329.jpg\"  class=\"wp-image-3348\" srcset=\"https:\/\/gewabintech.com\/wp-content\/uploads\/2023\/12\/db15aa2b4b46b15c5329.jpg 700w, https:\/\/gewabintech.com\/wp-content\/uploads\/2023\/12\/db15aa2b4b46b15c5329-600x600.jpg 600w, https:\/\/gewabintech.com\/wp-content\/uploads\/2023\/12\/db15aa2b4b46b15c5329-150x150.jpg 150w\" sizes=\"(max-width: 700px) 100vw, 700px\" title=\"Torre de arrefecimento de circuito cruzado \u2014 Ilustra\u00e7\u00e3o 3\" alt=\"Cross Circuit Cooling Tower\u63d2\u56fe3\" \/><\/figure>\n<p>&nbsp;<\/p>\n<p>Palavras-chave: torre de refrigera\u00e7\u00e3o de circuito cruzado, fornecedores, fabricantes, personalizada, pre\u00e7o, torres de refrigera\u00e7\u00e3o de circuito fechado, refrigera\u00e7\u00e3o de \u00e1gua em circuito fechado, torre de refrigera\u00e7\u00e3o h\u00famida de circuito fechado, torres de refrigera\u00e7\u00e3o e condensadores evaporativos OEM, torre de refrigera\u00e7\u00e3o de circuito fechado de fluxo combinado, torre de refrigera\u00e7\u00e3o combinada modularizada<\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>Working principle: 1. Internal circulation: The circulating water enters the surface cooler after heat exchange by the heat source, and the heat is sent to the outside through the surface cooler, and the cooled circulating water is sent to the heat source by the water pump. 2. External circulation: The spray water is sent from the water tank to the spray system. After the water is sprayed, it is in contact with the surface cooler for heat exchange. Some of the hot steam is discharged through the fan. The cooled spray water falls to the water tank and then circulates again. &nbsp; Product details &nbsp; Maintenance and maintenance of the closed cooling tower a. For the closed cooling tower, please keep the surface of the heat-dissipating coil (cooler) clean, ensure the surrounding air circulation, regularly clean the dust, oil stains and other debris on the heat exchanger to avoid affecting the air volume and heat dissipation effect, and regularly clean the spray. filter. b. If the closed cooling tower is deactivated for a period of time, the pump pump may be solidified by the deposit due to the deposition of water deposits. When the machine is turned on, the pump rotor must be turned loose to avoid the pump leaves not turning, resulting in burning of the fuse. c. After the closed cooling tower is used in a dusty environment for a period of time, the outer wall of the pipe may be fouled. After scaling, the cooling capacity of the equipment will be reduced. Descaling is recommended. &nbsp; Application &nbsp; Hot Tags: cross circuit cooling tower, suppliers, manufacturers, customized, price, Closed Circuit Cooling Towers, closed circuit water cooling, Closed Circuit Wet Cooling Tower, OEM Cooling Towers and Evaporative Condensers, Combined Flow Closed Circuit Cooling Tower, Modularized Combined Cooling Tower &nbsp;<\/p>","protected":false},"author":1,"featured_media":2334,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[47],"tags":[],"acf":[],"_links":{"self":[{"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/posts\/2344"}],"collection":[{"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/comments?post=2344"}],"version-history":[{"count":4,"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/posts\/2344\/revisions"}],"predecessor-version":[{"id":3932,"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/posts\/2344\/revisions\/3932"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/media\/2334"}],"wp:attachment":[{"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/media?parent=2344"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/categories?post=2344"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/tags?post=2344"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}