{"id":2479,"date":"2022-06-13T10:53:50","date_gmt":"2022-06-13T02:53:50","guid":{"rendered":"http:\/\/gewabin.wangluocloud.com\/?p=2479"},"modified":"2024-06-11T09:08:25","modified_gmt":"2024-06-11T01:08:25","slug":"precautions-of-replace-the-cooling-tower-packing","status":"publish","type":"post","link":"https:\/\/gewabintech.com\/pt\/news\/company-news\/precautions-of-replace-the-cooling-tower-packing\/","title":{"rendered":"Precau\u00e7\u00f5es a ter em conta na substitui\u00e7\u00e3o do enchimento da torre de arrefecimento"},"content":{"rendered":"<p>Quando \u00e9 necess\u00e1rio substituir o enchimento da torre de arrefecimento?<\/p>\n\n\n\n<p>Em geral, a torre de arrefecimento deve ser substitu\u00edda uma vez ap\u00f3s 5 a 8 anos de utiliza\u00e7\u00e3o normal. Na aus\u00eancia de manuten\u00e7\u00e3o regular, o enchimento deve ser substitu\u00eddo uma vez a cada 2 anos. Se ocorrer alguma das seguintes anomalias no enchimento da torre, este deve ser substitu\u00eddo atempadamente, para que a efici\u00eancia t\u00e9rmica de toda a torre possa atingir a meta pr\u00e9-definida.&nbsp;<\/p>\n\n\n\n<p>1. Incrusta\u00e7\u00e3o. O enchimento no corpo da torre forma incrusta\u00e7\u00f5es, que consistem geralmente em carbonato de c\u00e1lcio aderido ao enchimento, com aspeto semelhante a pedra e uma textura relativamente dura.&nbsp;<\/p>\n\n\n\n<p>2. Afundamento. Devido \u00e0 contamina\u00e7\u00e3o por cinzas de lama pesada, o enchimento do corpo da torre por vezes d\u00e1 origem a uma grande quantidade de algas, o que faz com que o enchimento se afunde e se torne inutiliz\u00e1vel.&nbsp;<\/p>\n\n\n\n<ol start=\"3\"><li>Envelhecimento. Ap\u00f3s uma utiliza\u00e7\u00e3o prolongada, o enchimento envelhece gradualmente, tornando-se fr\u00e1gil e propenso a partir-se devido \u00e0 eros\u00e3o causada pela \u00e1gua e pelo ar. O envelhecimento do enchimento das torres de alta temperatura \u00e9 mais r\u00e1pido do que o das torres comuns, sendo geralmente substitu\u00eddo uma vez a cada 4 a 6 anos.&nbsp;<\/li><\/ol>\n\n\n\n<p>4. Uma sele\u00e7\u00e3o incorreta ou um funcionamento inadequado causar\u00e3o danos graves ao enchimento da torre de arrefecimento. Todos os tipos de torres de arrefecimento t\u00eam valores de \u00edndice de trabalho de projeto, e uma sele\u00e7\u00e3o incorreta conduzir\u00e1 diretamente a danos graves e \u00e0 sucata da torre de arrefecimento. No que diz respeito a indicadores de funcionamento importantes, tais como a temperatura da \u00e1gua de entrada e a capacidade nominal, se o \u00edndice de funcionamento for superior ao valor de refer\u00eancia de projeto devido a uma opera\u00e7\u00e3o inadequada, isso tamb\u00e9m causar\u00e1 danos graves ao enchimento.<\/p>\n\n\n\n<p>www.gewabintech.com<\/p>","protected":false},"excerpt":{"rendered":"<p>When do you need to replace the cooling tower packing? Generally, the cooling tower needs to be replaced once after 5-8 years of normal use. In the absence of normal maintenance, the packing needs to be replaced once every 2 years. If the following abnormality occurs in the packing in the tower, it should be replaced in time, so that the thermal efficiency of the whole tower can reach the predetermined target.&nbsp; 1.Scaling. The packing in the tower body forms scale, which is generally calcium carbonate scale attached to the packing, which is stone-like and has a relatively hard texture.&nbsp; 2.Sinking. Due to the contamination of heavy mud ash, the tower body packing sometimes breeds a large number of algae organisms, which causes the packing to sink and cannot be used.&nbsp; Aging. After long-term use, the filler gradually becomes old, brittle and easy to break due to the erosion of water and air. The aging of high-temperature tower packing is faster than that of ordinary towers, and it is generally replaced once every 4 to 6 years.&nbsp; 4.Incorrect selection or improper operation will cause serious damage to the cooling tower packing. All types of cooling towers have design work index values, and incorrect selection will directly lead to serious damage and scrapping of the cooling tower. In terms of important working indicators such as inlet water temperature and configuration tonnage, if the working index is greater than the design index value due to improper operation, it will also cause serious damage to the packing. www.gewabintech.com<\/p>","protected":false},"author":1,"featured_media":2480,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[12],"tags":[],"acf":[],"_links":{"self":[{"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/posts\/2479"}],"collection":[{"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/comments?post=2479"}],"version-history":[{"count":2,"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/posts\/2479\/revisions"}],"predecessor-version":[{"id":3738,"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/posts\/2479\/revisions\/3738"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/media\/2480"}],"wp:attachment":[{"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/media?parent=2479"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/categories?post=2479"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/tags?post=2479"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}