{"id":2583,"date":"2020-06-12T15:38:02","date_gmt":"2020-06-12T07:38:02","guid":{"rendered":"http:\/\/gewabin.wangluocloud.com\/?p=2583"},"modified":"2023-12-19T15:51:29","modified_gmt":"2023-12-19T07:51:29","slug":"installation-of-evaporative-condenser-in-cold-storage","status":"publish","type":"post","link":"https:\/\/gewabintech.com\/pt\/news\/company-news\/installation-of-evaporative-condenser-in-cold-storage\/","title":{"rendered":"Instala\u00e7\u00e3o de condensador evaporativo em armaz\u00e9m frigor\u00edfico"},"content":{"rendered":"<p>O condensador evaporativo \u00e9 um equipamento de permuta de calor comummente utilizado para arrefecimento de c\u00e2maras frigor\u00edficas. Geralmente instalado na parte superior da sala de m\u00e1quinas, a estrutura do teto da sala de m\u00e1quinas necessita de um tratamento especial e tem de suportar o peso do condensador evaporativo.<\/p>\n\n\n\n<p>A instala\u00e7\u00e3o do condensador evaporativo de armazenagem a frio deve ser firme, fi\u00e1vel e bem ventilada. O topo da instala\u00e7\u00e3o deve ser 300 mm mais alto do que o edif\u00edcio adjacente, ou pelo menos n\u00e3o inferior \u00e0 altura do edif\u00edcio adjacente, de modo a evitar o retorno do ar quente e h\u00famido ao longo da parede para a entrada de ar; Se os requisitos acima n\u00e3o puderem ser cumpridos, deve ser instalada uma conduta de ar c\u00f3nica na sa\u00edda de ar no topo do condensador evaporativo durante a instala\u00e7\u00e3o para aumentar a velocidade do vento de sa\u00edda e a altura de exaust\u00e3o e reduzir o refluxo.<\/p>\n\n\n\n<p>A instala\u00e7\u00e3o do condensador evaporativo de armazenagem a frio tamb\u00e9m tem uma \u00fanica mesa e v\u00e1rios tipos de instala\u00e7\u00e3o paralela. Ao instalar, preste aten\u00e7\u00e3o \u00e0 dist\u00e2ncia dos edif\u00edcios vizinhos, geralmente preste aten\u00e7\u00e3o \u00e0s seguintes condi\u00e7\u00f5es:<\/p>\n\n\n\n<ol><li>Quando o condensador evaporativo tem paredes em todos os lados, o espa\u00e7amento m\u00ednimo no lado da entrada de ar durante a instala\u00e7\u00e3o deve ser de 1800 mm, e o espa\u00e7amento m\u00ednimo no lado sem entrada de ar \u00e9 de 900 mm.<\/li><li>Quando o condensador evaporativo \u00e9 uma parede s\u00f3lida em tr\u00eas lados e uma parede vazia no lado, o espa\u00e7amento m\u00ednimo no lado da entrada de ar deve ser de 900 mm, e o espa\u00e7amento m\u00ednimo no lado sem entrada de ar deve ser de 600 mm.<\/li><li>Quando dois condensadores evaporativos s\u00e3o instalados em paralelo, se ambos estiverem no lado da entrada de ar, a dist\u00e2ncia m\u00ednima entre eles deve ser de 800 mm; se um estiver no lado da entrada de ar e o outro estiver no lado sem entrada de ar, o espa\u00e7amento m\u00ednimo \u00e9 de 900 mm; se ambos n\u00e3o estiverem no lado da entrada de ar, o espa\u00e7amento m\u00ednimo \u00e9 de 600 mm.<\/li><\/ol>\n\n\n\n<p>Quando o condensador evaporativo utiliza um ventilador centr\u00edfugo ligado coaxialmente ou um tabuleiro de \u00e1gua com um aquecedor el\u00e9trico, nos casos 2 e 3 acima referidos, o espa\u00e7amento m\u00ednimo deve ser aumentado para facilitar a manuten\u00e7\u00e3o.<\/p>\n\n\n\n<p>Depois de garantir a dist\u00e2ncia entre o condensador evaporativo e o edif\u00edcio adjacente, prestar aten\u00e7\u00e3o ao tabuleiro de \u00e1gua do condensador evaporativo n\u00e3o deve estar a menos de 500 mm do solo durante a instala\u00e7\u00e3o, de modo a facilitar a liga\u00e7\u00e3o da tubagem, a dete\u00e7\u00e3o de fugas no tabuleiro de \u00e1gua e evitar que a sujidade do solo seja aspirada pelo ventilador.<\/p>\n\n\n\n<p>Durante a instala\u00e7\u00e3o correspondente do condensador evaporativo na c\u00e2mara frigor\u00edfica, o tubo de entrada de l\u00edquido do condensador evaporativo e o reservat\u00f3rio de l\u00edquido do tubo de arrefecimento de grupo \u00fanico podem ser utilizados para a equaliza\u00e7\u00e3o da press\u00e3o. A inclina\u00e7\u00e3o da sec\u00e7\u00e3o horizontal do tubo \u00e9 de 1\/50. Para o reservat\u00f3rio. Se a posi\u00e7\u00e3o de instala\u00e7\u00e3o da v\u00e1lvula for limitada pelas condi\u00e7\u00f5es de constru\u00e7\u00e3o, pode ser instalada no tubo principal, mas deve ser instalada abaixo da sa\u00edda de l\u00edquido 200 mm.<\/p>","protected":false},"excerpt":{"rendered":"<p>Evaporative condenser is a commonly used heat exchange equippment&nbsp;for cooling cold storage. Generally installed on the top of the machine room, the roof structure of the machine room needs special treatment, and it is required to bear the weight of the evaporative condenser. The cold storage evaporative condenser installation must be firm and reliable and well ventilated. The top of the installation should be 300mm higher than the adjacent building, or at least not lower than the height of the adjacent building, so as to avoid the return of hot and humid air along the wall to the air inlet; If the above requirements cannot be met, a tapered air duct should be installed on the air outlet at the top of the evaporative condenser during installation to increase the outlet wind speed and exhaust height and reduce backflow. Cold storage evaporative condenser installation also has a single table and multiple parallel installation types. When installing, pay attention to the distance from the neighboring buildings, generally pay attention to the following conditions: When the evaporative condenser is walled on all sides, the minimum spacing on the air inlet side during installation should be 1800 mm, and the minimum spacing on the non-air inlet side is 900 mm. When the evaporative condenser is a solid wall on three sides and an empty wall on the side, the minimum spacing on the air inlet side should be 900 mm, and the minimum spacing on the non-air inlet side should be 600 mm. When two evaporative condensers are installed in parallel, if both are on the air inlet side, the minimum distance between them should be 800mm; if-one is on the air inlet side and the other is on the non-air inlet side, The minimum spacing is 900mm; if both are not on the air inlet side, the minimum spacing is 600mm. When the evaporative condenser uses a coaxially connected centrifugal fan or a water tray with an electric heater, in the above 2 and 3 cases, the minimum spacing should be increased to facilitate maintenance. After ensuring the distance between the evaporative condenser and the adjacent building, pay attention to the water tray of the evaporative condenser should not be less than 500mm from the ground during installation, in order to facilitate pipeline connection, water tray leak detection and prevent ground dirt from being Fan suction. During the matching installation of the evaporative condenser in the cold storage, the liquid inlet pipe of the evaporative condenser and the liquid reservoir of the single group cooling pipe can be used for pressure equalization. The slope of the horizontal pipe section is 1\/50. To the reservoir. If the installation position of the valve is limited by the construction conditions, it can be installed on the main pipe, but it must be installed below the liquid outlet 200mm.<\/p>","protected":false},"author":1,"featured_media":2571,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[12],"tags":[],"acf":[],"_links":{"self":[{"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/posts\/2583"}],"collection":[{"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/comments?post=2583"}],"version-history":[{"count":1,"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/posts\/2583\/revisions"}],"predecessor-version":[{"id":2584,"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/posts\/2583\/revisions\/2584"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/media\/2571"}],"wp:attachment":[{"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/media?parent=2583"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/categories?post=2583"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/tags?post=2583"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}