{"id":2621,"date":"2020-06-10T09:24:56","date_gmt":"2020-06-10T01:24:56","guid":{"rendered":"http:\/\/gewabin.wangluocloud.com\/?p=2621"},"modified":"2023-12-20T09:48:31","modified_gmt":"2023-12-20T01:48:31","slug":"xplanation-and-solution-of-common-failures-of-closed-cooling-tower","status":"publish","type":"post","link":"https:\/\/gewabintech.com\/pt\/news\/company-news\/xplanation-and-solution-of-common-failures-of-closed-cooling-tower\/","title":{"rendered":"Explica\u00e7\u00e3o e resolu\u00e7\u00e3o de avarias comuns em torres de refrigera\u00e7\u00e3o fechadas"},"content":{"rendered":"<p>O ambiente de funcionamento das torres de refrigera\u00e7\u00e3o fechadas \u00e9 normalmente ao ar livre. Em compara\u00e7\u00e3o com os equipamentos instalados em recintos fechados, a probabilidade de avaria \u00e9 maior. Ent\u00e3o, quais s\u00e3o as avarias mais comuns associadas \u00e0 utiliza\u00e7\u00e3o de torres de refrigera\u00e7\u00e3o fechadas e como devemos reagir? Resumimos para todos as avarias mais comuns e as respetivas solu\u00e7\u00f5es relativas \u00e0s torres de refrigera\u00e7\u00e3o fechadas, na esperan\u00e7a de vos poder ajudar.<\/p>\n\n\n\n<p>Avarias comuns e solu\u00e7\u00f5es para torres de refrigera\u00e7\u00e3o fechadas:<\/p>\n\n\n\n<p>1: Temperatura an\u00f3mala da \u00e1gua numa torre de arrefecimento fechada<\/p>\n\n\n\n<p>Causas da avaria: m\u00e1 circula\u00e7\u00e3o de \u00e1gua na torre, caudal de \u00e1gua em circula\u00e7\u00e3o excessivo ou insuficiente na torre e fluxo de ar insuficiente proveniente do ventilador. No funcionamento do sistema de circula\u00e7\u00e3o, a circula\u00e7\u00e3o secund\u00e1ria do g\u00e1s quente \u00e9, no m\u00ednimo, cr\u00edtica para a temperatura. O radiador e a tubagem de distribui\u00e7\u00e3o de \u00e1gua s\u00e3o novamente afetados e devem ser verificados um a um e reparados imediatamente.<\/p>\n\n\n\n<p>Solu\u00e7\u00e3o: Em primeiro lugar, verifique o volume de \u00e1gua na torre para determinar se este est\u00e1 dentro dos par\u00e2metros normais. Um caudal de \u00e1gua excessivo provocar\u00e1 um aumento da temperatura da \u00e1gua. Em segundo lugar, verifique se h\u00e1 detritos e ar quente a circular no sistema de circula\u00e7\u00e3o e, por fim, verifique o volume de ar do ventilador. Se o volume de ar for insuficiente ou irregular, a obstru\u00e7\u00e3o far\u00e1 com que a temperatura da \u00e1gua aumente.<\/p>\n\n\n\n<p>2: O caudal de \u00e1gua na torre de arrefecimento diminui rapidamente<\/p>\n\n\n\n<p>Causa da avaria: O efeito mais concreto da redu\u00e7\u00e3o do caudal de \u00e1gua \u00e9 uma m\u00e1 dissipa\u00e7\u00e3o de calor do tubo de calor, o que raramente ocorre. O principal problema reside no entupimento dos orif\u00edcios de \u00e1gua ou dos filtros, o que resulta num abastecimento insuficiente de \u00e1gua, levando a um consumo cada vez maior de \u00e1gua. Se o n\u00edvel de \u00e1gua no dep\u00f3sito for demasiado baixo, isso tamb\u00e9m provocar\u00e1 uma falta de \u00e1gua na torre.<\/p>\n\n\n\n<p>3: Espalhar mais got\u00edculas de \u00e1gua:<\/p>\n\n\n\n<p>Causa da avaria: A causa mais comum deste fen\u00f3meno \u00e9 a velocidade de rota\u00e7\u00e3o excessiva do tubo de distribui\u00e7\u00e3o de \u00e1gua, resultante de um controlo deficiente. Outras causas incluem excesso de \u00e1gua no dep\u00f3sito de distribui\u00e7\u00e3o, aletas entupidas ou a utiliza\u00e7\u00e3o de uma pe\u00e7a inadequada no guia de \u00e1gua. Do ponto de vista funcional, o problema do gotejamento \u00e9 causado pelo excesso de \u00e1gua em circula\u00e7\u00e3o na torre.<\/p>\n\n\n\n<p>Solu\u00e7\u00e3o: Verifique primeiro o volume de \u00e1gua de arrefecimento na torre de arrefecimento, regule o volume de \u00e1gua atempadamente, reduza o volume de \u00e1gua em circula\u00e7\u00e3o, ajuste ou substitua o defletor de \u00e1gua, desobstrua as aletas entupidas atempadamente e substitua e limpe os acess\u00f3rios da torre de arrefecimento atempadamente.<\/p>","protected":false},"excerpt":{"rendered":"<p>The operating environment of enclosed cooling towers is usually outdoors. Compared with indoor equipment, the possibility of failure is higher. So, what are the common failures of using enclosed cooling towers, and how should we respond? We have summarized the common failures and solutions of closed cooling towers for everyone, and hope to help you. Common failures and solutions of enclosed cooling towers: 1: Abnormal water temperature of closed cooling tower Causes of failure: Poor water circulation in the tower, too much or too little circulating water flow in the tower, and insufficient air flow from the fan. In the process of the circulation system, the secondary circulation of hot gas is at least critical to the temperature. The radiator and water distribution pipe are affected again and must be checked one by one and dealt with immediately. Solution: The first is to query the water volume in the tower to check whether the water volume meets the normal specifications. Excessive water flow will cause the water temperature to rise. Secondly, check whether there is wood and hot air circulating in the circulation system, and finally check the air volume of the fan. If the air volume is insufficient or uneven, sealing will cause the water temperature to rise. 2: The water flow in the cooling tower drops rapidly Cause of failure: The most practical effect of reducing water flow is poor heat dissipation from the heat pipe, which rarely occurs. The key is clogged water holes or filters, resulting in insufficient water supply, resulting in more and more water. If the water level in the water tank is too low, it will also cause insufficient water in the tower. 3: Splash more water droplets: Cause of failure: The most common cause of this phenomenon is that the rotation speed of the water distribution pipe is too fast, which is caused by poor control. Others include too much water in the distribution tank, clogged fins or the wrong part of the water guide. Functionally, the dripping problem is caused by too much circulating water in the tower. Solution: First check the cooling water volume in the cooling tower, control the water volume in time, reduce the circulating water volume, adjust or replace the new water baffle, open the blocked fins in time, and replace and clean the new cooling tower accessories in time.<\/p>","protected":false},"author":1,"featured_media":2622,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[12],"tags":[],"acf":[],"_links":{"self":[{"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/posts\/2621"}],"collection":[{"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/comments?post=2621"}],"version-history":[{"count":2,"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/posts\/2621\/revisions"}],"predecessor-version":[{"id":2624,"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/posts\/2621\/revisions\/2624"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/media\/2622"}],"wp:attachment":[{"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/media?parent=2621"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/categories?post=2621"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/gewabintech.com\/pt\/wp-json\/wp\/v2\/tags?post=2621"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}